Literature DB >> 19733135

Rapid determination of cyanide in human plasma and urine by gas chromatography-mass spectrometry with two-step derivatization.

Guojie Liu1, Junting Liu, Kenji Hara, Yanfang Wang, Yanping Yu, Lina Gao, Ling Li.   

Abstract

Cyanide (CN) is a powerful poison and rapidly toxic agent. Because of its wide availability and high toxicity, quantification of CN in blood and urine is frequently required in clinical and forensic practice. We present a sensitive and less time consuming method based on solid-supported liquid-liquid extraction (SLE) and gas chromatography-mass spectrometry (GC-MS) with two-step derivatization for determination of CN in plasma and urine. Buffer solution, 1,3,5-tribromobenzene (internal standard) and benzaidehyde were added to sample to complete the first-step derivatization. Then the analytes were poured onto the column of diatomaceous earth, eluted with n-hexane containing 0.4% of heptafluorobutyryl chloride (HFB-Cl) to complete the second-step derivatization forming the final analyte, heptafluoro-butyric acid-alpha-cyanobenzyl ester. This method was linear (r(2)=0.9988, 0.9993), reproducible (intra-day RSD=4.37-7.24%, 3.19-5.74%; inter-day RSD=5.13-7.63%, 4.31-6.69%), accurate (recoveries=90.58-115.56%, 93.01-114.6%) and sensitive (LOD=0.04, 0.01microg/mL) for plasma and urine, respectively. The total time was about 25min. This method was successfully applied to the analysis of blood sample and urine sample collected from a victim who died as a result of ingestion of potassium cyanide.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19733135     DOI: 10.1016/j.jchromb.2009.07.029

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  7 in total

Review 1.  Recent developments in cyanide detection: a review.

Authors:  Jian Ma; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2010-06-04       Impact factor: 6.558

2.  Rapid point of care analyzer for the measurement of cyanide in blood.

Authors:  Jian Ma; Shin-Ichi Ohira; Santosh K Mishra; Mahitti Puanngam; Purnendu K Dasgupta; Sari B Mahon; Matthew Brenner; William Blackledge; Gerry R Boss
Journal:  Anal Chem       Date:  2011-05-10       Impact factor: 6.986

3.  Automatic Supported Liquid Extraction (SLE) Coupled with HILIC-MS/MS: An Application to Method Development and Validation of Erlotinib in Human Plasma.

Authors:  Jiongwei Pan; Xiangyu Jiang; Yu-Luan Chen
Journal:  Pharmaceutics       Date:  2010-04-01       Impact factor: 6.321

4.  Direct injection HILIC-MS/MS analysis of darunavir in rat plasma applying supported liquid extraction.

Authors:  Bokka Ramesh; Nemali Manjula; Sistla Ramakrishna; Potturi Sita Devi
Journal:  J Pharm Anal       Date:  2014-05-20

5.  Determination of cyanide in urine and saliva samples by ion chromatography with pulsed amperometric detection.

Authors:  Ewa Jaszczak; Sylwia Narkowicz; Jacek Namieśnik; Żaneta Polkowska
Journal:  Monatsh Chem       Date:  2017-06-23       Impact factor: 1.451

Review 6.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

7.  Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

Authors:  Ewa Jaszczak; Marek Ruman; Sylwia Narkowicz; Jacek Namieśnik; Żaneta Polkowska
Journal:  J Anal Methods Chem       Date:  2017-11-21       Impact factor: 2.193

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.