Literature DB >> 19731039

A microfluidic device for separation of amniotic fluid mesenchymal stem cells utilizing louver-array structures.

Huei-Wen Wu1, Xi-Zhang Lin, Shiaw-Min Hwang, Gwo-Bin Lee.   

Abstract

Human mesenchymal stem cells can differentiate into multiple lineages for cell therapy and, therefore, have attracted considerable research interest recently. This study presents a new microfluidic device for bead and cell separation utilizing a combination of T-junction focusing and tilted louver-like structures. For the first time, a microfluidic device is used for continuous separation of amniotic stem cells from amniotic fluids. An experimental separation efficiency as high as 82.8% for amniotic fluid mesenchymal stem cells is achieved. Furthermore, a two-step separation process is performed to improve the separation efficiency to 97.1%. These results are based on characterization experiments that show that this microfluidic chip is capable of separating beads with diameters of 5, 10, 20, and 40 microm by adjusting the volume-flow-rate ratio between the flows in the main and side channels of the T-junction focusing structure. An optimal volume-flow-rate ratio of 0.5 can lead to high separation efficiencies of 87.8% and 85.7% for 5-microm and 10-microm beads, respectively, in a one-step separation process. The development of this microfluidic chip may be promising for future research into stem cells and for cell therapy.

Entities:  

Mesh:

Year:  2009        PMID: 19731039     DOI: 10.1007/s10544-009-9349-x

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  4 in total

Review 1.  Sample pretreatment and nucleic acid-based detection for fast diagnosis utilizing microfluidic systems.

Authors:  Jung-Hao Wang; Chih-Hung Wang; Gwo-Bin Lee
Journal:  Ann Biomed Eng       Date:  2011-12-07       Impact factor: 3.934

2.  Stem cells in microfluidics.

Authors:  Huei-Wen Wu; Chun-Che Lin; Gwo-Bin Lee
Journal:  Biomicrofluidics       Date:  2011-03-30       Impact factor: 2.800

Review 3.  Microfluidic sample preparation for diagnostic cytopathology.

Authors:  Albert J Mach; Oladunni B Adeyiga; Dino Di Carlo
Journal:  Lab Chip       Date:  2013-03-21       Impact factor: 6.799

4.  Self-rotation of cells in an irrotational AC E-field in an opto-electrokinetics chip.

Authors:  Long-Ho Chau; Wenfeng Liang; Florence Wing Ki Cheung; Wing Keung Liu; Wen Jung Li; Shih-Chi Chen; Gwo-Bin Lee
Journal:  PLoS One       Date:  2013-01-08       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.