In vivo comparison of knee kinematics before and after high-flexion posterior cruciate-retaining total knee arthroplasty.

Atsushi Kitagawa1, Nobuhiro Tsumura, Takaaki Chin, Kazuyoshi Gamada, Scott A Banks, Masahiro Kurosaka.   

Abstract

The objectives of this study were to compare preoperative and postoperative knee kinematics for subjects implanted with flexion-enhanced posterior cruciate-retaining total knee arthroplasty during deep flexion and to examine flexion performance of the prosthesis design. Three-dimensional kinematics was analyzed by fluoroscopic examinations of subjects using a single-plane model-image registration technique. Preoperatively, knee kinematics demonstrated small posterior femoral translation and limited axial rotation. These motions differed significantly from patterns previously reported for normal knees. Postoperatively, flexion performance was maintained, averaging 130 degrees , and kinematic patterns were similar to preoperative patterns. Although total knee arthroplasty can reduce pain and maintain functional performance, it appears that the characteristics of varus arthritic knee mechanics persist after arthroplasty. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19729277     DOI: 10.1016/j.arth.2009.07.008

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  Patients with no functional improvement after total knee arthroplasty show different kinematics.

Authors:  Jörg Lützner; Stephan Kirschner; Klaus-Peter Günther; Melinda K Harman
Journal:  Int Orthop       Date:  2012-05-29       Impact factor: 3.075

2.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

3.  Intra-operative gaps affect outcome and postoperative kinematics in vivo following cruciate-retaining total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Tetsuya Tomita; Hirofumi Sasaki; Yoriko Touten; Yuusuke Fujiwara; Mitsuo Ochi
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

4.  How does TKA kinematics vary with transverse plane alignment changes in a contemporary implant?

Authors:  William M Mihalko; Devin J Conner; Rodney Benner; John L Williams
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

5.  Weight-bearing status affects in vivo kinematics following mobile-bearing unicompartmental knee arthroplasty.

Authors:  Kenichi Kono; Hiroshi Inui; Tetsuya Tomita; Takaharu Yamazaki; Shuji Taketomi; Ryota Yamagami; Kohei Kawaguchi; Kazuomi Sugamoto; Sakae Tanaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-02-13       Impact factor: 4.342

6.  Effect of tibial slope changes on femorotibial contact kinematics after cruciate-retaining total knee arthroplasty.

Authors:  Xi-Qing Pan; A-Qin Peng; Fei Wang; Feng Li; Xi-Zeng Nie; Xi Yang; Gang Ji; Xiao-Meng Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-25       Impact factor: 4.342

7.  Different femorotibial contact on the weight-bearing: midflexion between normal and varus aligned knees after total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Tetsuya Tomita; Kenji Kashiwagi; Amiko Inoue; Mikiya Sawa; Yuki Ota
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-25       Impact factor: 4.342

8.  Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements.

Authors:  C Belvedere; S Tamarri; D P Notarangelo; A Ensini; A Feliciangeli; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-02       Impact factor: 4.342

9.  Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor.

Authors:  Tokio Matsuzaki; Tomoyuki Matsumoto; Seiji Kubo; Hirotsugu Muratsu; Takehiko Matsushita; Yohei Kawakami; Kazunari Ishida; Shinya Oka; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

10.  Partial restoration of knee kinematics in severe valgus deformity using the medial-pivot total knee arthroplasty.

Authors:  Atsushi Kitagawa; Kazunari Ishida; Takaaki Chin; Nobuhiro Tsumura; Tetsushiro Iguchi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-29       Impact factor: 4.342

View more