Literature DB >> 19728002

Compared with dual nerve stimulation, ultrasound guidance shortens the time for infraclavicular block performance.

Richard Brull1, Mario Lupu, Anahi Perlas, Vincent W S Chan, Colin J L McCartney.   

Abstract

PURPOSE: The success rate for infraclavicular brachial plexus block using nerve stimulation reportedly ranges from 60 to 80%. Ultrasound guidance may be associated with greater success. This study compared ultrasound guided infraclavicular block with a dual motor endpoint nerve stimulation technique.
METHODS: One hundred three hand surgery patients were randomized to receive either ultrasound-guided (ultrasound group) or dual motor endpoint nerve stimulation (stimulation group) infraclavicular block using 2% lidocaine 15 mL and 0.5% bupivacaine 15 mL with epinephrine. Block success was defined as loss of sensation to pinprick in each of the radial, ulnar, median, and musculocutaneous nerve distributions when measured 20 min after block performance. Block performance time, readiness for surgery (no supplemental block, skin infiltration, or general anesthesia), and complications were also assessed.
RESULTS: Patient characteristics were similar between groups. Success rate was 92% in the ultrasound group and 80% in the stimulation group (P = 0.18). Block performance time was shorter in the ultrasound group (median 5 min) compared with the stimulation group (median 10.5 min) (P < 0.001). Paresthesiae were more frequent in the stimulation group (45%) than in the ultrasound group (6%) (P < 0.001). After final injection, more patients were ready for surgery in the ultrasound group (85%) than in the stimulation group (65%) (P = 0.04). At 1 week postoperatively, complications were minor and transient and did not differ between groups.
CONCLUSION: There was no statistically significant difference in the success rate between ultrasound guidance and dual motor endpoint stimulation for infraclavicular block. However, ultrasound guidance shortens performance time and improves readiness for surgery compared with dual motor endpoint stimulation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19728002     DOI: 10.1007/s12630-009-9170-2

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

Review 1.  Ultrasound guidance for upper and lower limb blocks.

Authors:  Sharon R Lewis; Anastasia Price; Kevin J Walker; Ken McGrattan; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-09-11

2.  Ultrasound guidance for deep peripheral nerve blocks: a brief review.

Authors:  Anupama Wadhwa; Sunitha Kanchi Kandadai; Sujittra Tongpresert; Detlef Obal; Ralf Erich Gebhard
Journal:  Anesthesiol Res Pract       Date:  2011-07-27

3.  Role of positioning posterior cord on coracoid approach brachial plexus block guided by nerve stimulator: Compared with guided by ultrasound.

Authors:  Wensheng He; Zhuo Liu; Zhenyu Wu; Wenchao Liu; Haijun Sun; Xiaochun Yang
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

4.  Peripheral Nerve Injury After Upper-Extremity Surgery Performed Under Regional Anesthesia: A Systematic Review.

Authors:  Max Lester Silverstein; Ruth Tevlin; Kenneth Elliott Higgins; Rachel Pedreira; Catherine Curtin
Journal:  J Hand Surg Glob Online       Date:  2022-06-04

5.  Ultrasound does not shorten the duration of procedure but provides a faster sensory and motor block onset in comparison to nerve stimulator in infraclavicular brachial plexus block.

Authors:  Walid Trabelsi; Mondher Belhaj Amor; Mohamed Anis Lebbi; Chiheb Romdhani; Sami Dhahri; Mustapha Ferjani
Journal:  Korean J Anesthesiol       Date:  2013-04-22

Review 6.  Medical devices for the anesthetist: current perspectives.

Authors:  Jerry Ingrande; Hendrikus Jm Lemmens
Journal:  Med Devices (Auckl)       Date:  2014-03-25

7.  Comparison of RIVA and infraclavicular block in forearm and hand surgery.

Authors:  Zubeyir Sivrikaya; Guldem Turan; Reyhan Cetiner; Dilek Subasi; Gulcin Ozturk; Asu Ozgultekin; Osman Ekinci
Journal:  North Clin Istanb       Date:  2017-08-26
  7 in total