Literature DB >> 19720170

Direct determination of melamine in dairy products by gas chromatography/mass spectrometry with coupled column separation.

Xiao-min Xu1, Yi-ping Ren, Yun Zhu, Zeng-xuan Cai, Jian-long Han, Bai-fen Huang, Yan Zhu.   

Abstract

A coupled capillary column system was developed for the qualitative and quantitative determination of melamine with isotope internal standard in dairy products by gas chromatography/mass spectrometry (GC/MS) without derivatization. A 30 m of DB-5 ms ((5%-phenyl)-methylpolysiloxane, 0.25 mm i.d., 0.25 microm df) coupled with a 1.5 m of Innowax (polyethylene glycol, 0.32 mm i.d., 0.25 microm df) by a quartz capillary column connector was introduced as separation column. Three advantages were discussed for the coupled system. The sample was fortified with a ring-labeled (13)C(3)(15)N(3)-melamine as an isotope internal standard and extracted by 1% of trichloroacetic acid aqueous solution. 2.2% of lead acetate solution was then added to deposit protein in the sample matrix. After purification by cation exchange cartridge, the sample solution was directly injected and detected by GC/MS. A six-point calibration curve ranging from 0.05 to 2 mg kg(-1) of melamine in sample was used to establish instrument response. The recovery was 93.9-102% with relative standard deviation from 3.1 to 8.7% when isotope internal standard used. The calculated method detection limit was 0.01 mg kg(-1).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19720170     DOI: 10.1016/j.aca.2009.04.026

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  13 in total

Review 1.  Recent developments in the detection of melamine.

Authors:  Yuan Liu; Ewen E D Todd; Qiang Zhang; Jiang-rong Shi; Xian-jin Liu
Journal:  J Zhejiang Univ Sci B       Date:  2012-07       Impact factor: 3.066

2.  13C NMR detection of non-protein nitrogen substance adulteration in animal feed.

Authors:  Chengxiang Zhao; Tongtong Wang; Furong Chen; Yongyue Sun; Gang Chen
Journal:  Anal Bioanal Chem       Date:  2022-02-05       Impact factor: 4.142

3.  Visual and Optical Absorbance Detection of Melamine in Milk by Melamine-Induced Aggregation of Gold Nanoparticles.

Authors:  Shafiquzzaman Siddiquee; Suryani Saallah; Noor Aini Bohari; Gilbert Ringgit; Jumardi Roslan; Laila Naher; Nur Fatihah Hasan Nudin
Journal:  Nanomaterials (Basel)       Date:  2021-04-28       Impact factor: 5.076

4.  Colorimetric detection of melamine in milk by using gold nanoparticles-based LSPR via optical fibers.

Authors:  Keke Chang; Shun Wang; Hao Zhang; Qingqian Guo; Xinran Hu; Zhili Lin; Haifeng Sun; Min Jiang; Jiandong Hu
Journal:  PLoS One       Date:  2017-05-05       Impact factor: 3.240

5.  A Surface Plasmon Resonance-Based Optical Fiber Probe Fabricated with Electropolymerized Molecular Imprinting Film for Melamine Detection.

Authors:  Wei Li; Yongping Zheng; Tingwei Zhang; Songjie Wu; Jue Zhang; Jing Fang
Journal:  Sensors (Basel)       Date:  2018-03-09       Impact factor: 3.576

6.  Determination of melamine in soil samples using surfactant-enhanced hollow fiber liquid phase microextraction followed by HPLC-UV using experimental design.

Authors:  Ali Sarafraz Yazdi; Samaneh Raouf Yazdinezhad; Tahereh Heidari
Journal:  J Adv Res       Date:  2014-11-08       Impact factor: 10.479

7.  Detection of melamine in feed using liquid-liquid extraction treatment combined with surface-enhanced Raman scattering spectroscopy.

Authors:  Jie Cheng; Shi Wang; Xiao-Ou Su
Journal:  PLoS One       Date:  2014-09-22       Impact factor: 3.240

8.  Penetration Depth Measurement of Near-Infrared Hyperspectral Imaging Light for Milk Powder.

Authors:  Min Huang; Moon S Kim; Kuanglin Chao; Jianwei Qin; Changyeun Mo; Carlos Esquerre; Stephen Delwiche; Qibing Zhu
Journal:  Sensors (Basel)       Date:  2016-03-25       Impact factor: 3.576

9.  Highly Sensitive Detection of Melamine Using a One-Step Sample Treatment Combined with a Portable Ag Nanostructure Array SERS Sensor.

Authors:  Jie Cheng; Xiao-Ou Su; Yue Yao; Caiqin Han; Shi Wang; Yiping Zhao
Journal:  PLoS One       Date:  2016-04-27       Impact factor: 3.240

10.  Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples.

Authors:  Xinran Hu; Keke Chang; Shun Wang; Xiaoquan Sun; Jiandong Hu; Min Jiang
Journal:  PLoS One       Date:  2018-08-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.