Literature DB >> 19719814

Electrical impedance tomography and heterogeneity of pulmonary perfusion and ventilation in porcine acute lung injury.

A Fagerberg1, S Söndergaard, S Karason, A Aneman.   

Abstract

BACKGROUND: The heterogeneity of pulmonary ventilation (V), perfusion (Q) and V/Q matching impairs gas exchange in an acute lung injury (ALI). This study investigated the feasibility of electrical impedance tomography (EIT) to assess the V/Q distribution and matching during an endotoxinaemic ALI in pigs.
METHODS: Mechanically ventilated, anaesthetised pigs (n=11, weight 30-36 kg) were studied during an infusion of endotoxin for 150 min. Impedance changes related to ventilation (Z(V)) and perfusion (Z(Q)) were monitored globally and bilaterally in four regions of interest (ROIs) of the EIT image. The distribution and ratio of Z(V) and Z(Q) were assessed. The alveolar-arterial oxygen difference, venous admixture, fractional alveolar dead space and functional residual capacity (FRC) were recorded, together with global and regional lung compliances and haemodynamic parameters. Values are mean+/-standard deviation (SD) and regression coefficients.
RESULTS: Endotoxinaemia increased the heterogeneity of Z(Q) but not Z(V). Lung compliance progressively decreased with a ventral redistribution of Z(V). A concomitant dorsal redistribution of Z(Q) resulted in mismatch of global (from Z(V)/Z(Q) 1.1+/-0.1 to 0.83+/-0.3) and notably dorsal (from Z(V)/Z(Q) 0.86+/-0.4 to 0.51+/-0.3) V and Q. Changes in global Z(V)/Z(Q) correlated with changes in the alveolar-arterial oxygen difference (r(2)=0.65, P<0.05), venous admixture (r(2)=0.66, P<0.05) and fractional alveolar dead space (r(2)=0.61, P<0.05). Decreased end-expiratory Z(V) correlated with decreased FRC (r(2)=0.74, P<0.05).
CONCLUSIONS: EIT can be used to assess the heterogeneity of regional pulmonary ventilation and perfusion and V/Q matching during endotoxinaemic ALI, identifying pivotal pathophysiological changes.

Entities:  

Mesh:

Year:  2009        PMID: 19719814     DOI: 10.1111/j.1399-6576.2009.02103.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

1.  Low tidal volume pressure support versus controlled ventilation in early experimental sepsis in pigs.

Authors:  Alexander Ziebart; Erik K Hartmann; Rainer Thomas; Tanghua Liu; Bastian Duenges; Arno Schad; Marc Bodenstein; Serge C Thal; Matthias David
Journal:  Respir Res       Date:  2014-09-06

Review 2.  Biomedical engineer's guide to the clinical aspects of intensive care mechanical ventilation.

Authors:  Vincent J Major; Yeong Shiong Chiew; Geoffrey M Shaw; J Geoffrey Chase
Journal:  Biomed Eng Online       Date:  2018-11-12       Impact factor: 2.819

Review 3.  A Review of EMG-, FMG-, and EIT-Based Biosensors and Relevant Human-Machine Interactivities and Biomedical Applications.

Authors:  Zhuo Zheng; Zinan Wu; Runkun Zhao; Yinghui Ni; Xutian Jing; Shuo Gao
Journal:  Biosensors (Basel)       Date:  2022-07-12

4.  Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury.

Authors:  Constantin J C Trepte; Charles R Phillips; Josep Solà; Andy Adler; Sebastian A Haas; Michael Rapin; Stephan H Böhm; Daniel A Reuter
Journal:  Crit Care       Date:  2016-01-22       Impact factor: 9.097

  4 in total