Literature DB >> 19716656

Disinfection characteristics of the dissolved organic fractions at several stages of a conventional drinking water treatment plant in Southern China.

Zhen-Ye Zhao1, Ji-Dong Gu, Hai-Bo Li, Xiao-Yan Li, Kenneth Mei-Yee Leung.   

Abstract

Dissolved organic matter (DOM) influences many aspects of drinking water treatment, including the formation of harmful disinfection by-products (DBPs) when disinfectants are applied. DOM was isolated and fractionated using membrane ultra-filtration (UF) and reverse osmosis (RO) to eight individual fractions based on molecular weight cut-offs from a conventional surface water treatment plant (WTP) in Guangzhou of PR China. Molecular weights of these eight fractions were further calibrated using high performance size exclusion chromatography (HPSEC) and they ranged from 0.36 to 182.6 kDa. Fractions with molecular weight <0.80 kDa obtained by YC-05 UF membrane and RO were the major ones in all four stages of the water treatment processes; both ZM-500 and YM-100 membranes showed the highest removal efficiency when coupling with conventional coagulation and sedimentation processes. The elemental analysis showed that YC-05 fraction had greater polarity and aromaticity than any of the others. Furthermore, disinfection characteristics and trihalomethane formation potential (THMFP) were determined for all DOM fractions obtained in this study. YC-05 fraction was the major precursor for trihalomethane (THMs) formation among the samples tested and could be removed effectively by particulate activated carbon (PAC) adsorption. RO fraction could not be removed by PAC adsorption and, as a result, consumed more chlorine in the disinfection process. The results suggested that advanced drinking water treatment should focus on the removal of low molecular weight DOM in the source water.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19716656     DOI: 10.1016/j.jhazmat.2009.07.101

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  2 in total

1.  Multistep, microvolume resin fractionation combined with 3D fluorescence spectroscopy for improved DOM characterization and water quality monitoring.

Authors:  Qunshan Wei; Changzhou Yan; Jianshe Liu; Zhuanxi Luo; Qiujin Xu; Xian Zhang; Christopher W K Chow; Meng Nan Chong
Journal:  Environ Monit Assess       Date:  2012-07-20       Impact factor: 2.513

2.  Fate of natural organic matter at a full-scale Drinking Water Treatment Plant in Greece.

Authors:  A Papageorgiou; N Papadakis; D Voutsa
Journal:  Environ Sci Pollut Res Int       Date:  2015-09-24       Impact factor: 4.223

  2 in total