Literature DB >> 19716053

Clinical experience using the Levitronix CentriMag system for temporary right ventricular mechanical circulatory support.

Jay K Bhama1, Robert L Kormos, Yoshiya Toyoda, Jeffrey J Teuteberg, Kenneth R McCurry, Michael P Siegenthaler.   

Abstract

BACKGROUND: Short-term mechanical circulatory support may be lifesaving in patients with right ventricular (RV) failure related to post-cardiotomy cardiogenic shock (PCCS), cardiac transplantation (CTx), and long-term therapy with a left ventricular assist device (LVAD). This study evaluates our clinical experience using the CentriMag (Levitronix LLC, Waltham, Mass) system for temporary mechanical RV support.
METHODS: A retrospective review was performed of 29 patients (mean age, 57 +/- 14 years) in whom the CentriMag system was used for RV support from September 2005 to March 2008.
RESULTS: The indication for RV support was PCCS in 7 (24%), CTx in 10 (35%), and LVAD placement in 12 (41%). The mean support time was 8 +/- 8 days. The device was successfully weaned in 3 PCCS patients (43%), 7 CTx patients (70%), and 7 LVAD patients (58%). Complications included major infection (pneumonia, sepsis, or LVAD pocket infection) in 13 (45%), arrhythmia in 13 (45%), reoperation for bleeding in 10 (35%), stroke/encephalopathy in 3 (10%), and air embolism in 1 (3%). Early mortality (< 30 days or before discharge) occurred in 14 patients (48%) of which 9 (31%) died with the device in place. Late death occurred in 2 of 15 patients (13%) who survived to discharge. There were no device failures.
CONCLUSIONS: The CentriMag system provides effective temporary mechanical circulatory support for RV failure. Ease of implantation and a high rate of successful device weaning justify the use of the CentriMag system for temporary RV support.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19716053     DOI: 10.1016/j.healun.2009.04.015

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  25 in total

Review 1.  Novel Insights and Treatment Strategies for Right Heart Failure.

Authors:  Weiqin Lin; Ai-Ling Poh; W H Wilson Tang
Journal:  Curr Heart Fail Rep       Date:  2018-06

2.  Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes.

Authors:  Hiroo Takayama; Lori Soni; Bindu Kalesan; Lauren K Truby; Takeyoshi Ota; Sophia Cedola; Zain Khalpey; Nir Uriel; Paolo Colombo; Donna M Mancini; Ulrich P Jorde; Yoshifumi Naka
Journal:  Circ Heart Fail       Date:  2014-07-15       Impact factor: 8.790

Review 3.  Management of right ventricular failure in the era of ventricular assist device therapy.

Authors:  Michael L Craig
Journal:  Curr Heart Fail Rep       Date:  2011-03

4.  Preclinical study of a novel hydrodynamically levitated centrifugal pump for long-term cardiopulmonary support : In vivo performance during percutaneous cardiopulmonary support.

Authors:  Tomonori Tsukiya; Toshihide Mizuno; Yoshiaki Takewa; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2015-05-15       Impact factor: 1.731

Review 5.  Assessment and treatment of right ventricular failure.

Authors:  Marc A Simon
Journal:  Nat Rev Cardiol       Date:  2013-02-12       Impact factor: 32.419

6.  Platelet activation after implantation of the Levitronix PediVAS in the ovine model.

Authors:  Carl A Johnson; Venkat Shankarraman; Peter D Wearden; Ergin Kocyildirim; Timothy M Maul; John D Marks; J Scott Richardson; Barry N Gellman; Harvey S Borovetz; Kurt A Dasse; William R Wagner
Journal:  ASAIO J       Date:  2011 Nov-Dec       Impact factor: 2.872

Review 7.  Mechanical circulatory support: devices, outcomes and complications.

Authors:  Carmelo A Milano; Alan A Simeone
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

8.  Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantation.

Authors:  Assad Haneya; Alois Philipp; Thomas Puehler; Leopold Rupprecht; Reinhard Kobuch; Michael Hilker; Christof Schmid; Stephan W Hirt
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

Review 9.  What is the optimal mode of mechanical support in transplanted patients with acute graft failure?

Authors:  Marian Urban; Ondrej Szarszoi; Jan Pirk; Ivan Netuka
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-12-30

10.  Temporary assist device support for the right ventricle: pre-implant and post-implant challenges.

Authors:  Michael Dandel; Roland Hetzer
Journal:  Heart Fail Rev       Date:  2018-03       Impact factor: 4.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.