Literature DB >> 19709835

CT fluoroscopy guided transpleural cutting needle biopsy of small (≤2.5 cm) subpleural pulmonary nodules.

Helmut Prosch1, Elisabeth Oschatz, Edith Eisenhuber, Helmut Wohlschlager, Gerhard H Mostbeck.   

Abstract

PURPOSE: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions.
MATERIAL AND METHODS: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura.
RESULTS: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required.
CONCLUSION: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.
Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19709835     DOI: 10.1016/j.ejrad.2009.07.021

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Utility of contrast-enhanced ultrasound with SonoVue in biopsy of small subpleural nodules.

Authors:  Jinlin Wang; Dazhi Zhou; Xiaohong Xie; Panxiao Shen; Yunxiang Zeng
Journal:  Int J Clin Exp Med       Date:  2015-09-15

2.  Core-needle biopsy under CT fluoroscopy guidance and fine-needle aspiration cytology: Comparison of diagnostic yield in the diagnosis of lung and mediastinum tumors. Analysis of frequency and types of complications.

Authors:  Przemysław Szlęzak; Ewa Srutek; Tomasz Gorycki; Janusz Kowalewski; Michał Studniarek
Journal:  Pol J Radiol       Date:  2014-07-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.