Literature DB >> 19707192

Improved oral intake after palliative duodenal stenting for malignant obstruction: a prospective multicenter clinical trial.

Michael Piesman1, Richard A Kozarek, John J Brandabur, Douglas K Pleskow, Ram Chuttani, Viktor E Eysselein, William B Silverman, John J Vargo, Irving Waxman, Marc F Catalano, Todd H Baron, Willis G Parsons, Adam Slivka, David L Carr-Locke.   

Abstract

OBJECTIVES: We sought to test the hypothesis that placement of a new nitinol duodenal self-expandable metallic stent (SEMS) for palliation of malignant gastroduodenal obstruction is effective and safe in allowing patients to tolerate an oral diet.
METHODS: In a prospective multicenter study, SEMSs (Duodenal WallFlex, Boston Scientific) were placed to alleviate gastroduodenal obstruction in inoperable patients without the ability to tolerate solid food. The primary study end point was improvement in oral intake monitored according to the 4-point Gastric Outlet Obstruction Scoring System (GOOSS) up to 24 weeks after stent placement.
RESULTS: Forty-three patients received SEMSs, which were successfully deployed on the first attempt in 41 cases (95%) and the second attempt in two (5%). Within 1 day and 7 days after SEMS placement, 52% and 75% of patients, respectively, benefited from a GOOSS increase > or =1. Resumption of solid food intake (GOOSS 2-3) was attained by 56% of patients within 7 days and 80% by 28 days. Of the patients attaining GOOSS 2-3, 48% remained on solid food until death or last follow-up. Device-related adverse events included stent occlusion/malfunction in 9% of patients and perforation in 5% of patients.
CONCLUSIONS: Duodenal WallFlex stent placement promptly improves oral intake in a majority of inoperable patients with malignant gastroduodenal obstruction. In approximately half the patients achieving GOOSS 2-3, the capacity for solid food intake endures until death or last follow-up.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19707192     DOI: 10.1038/ajg.2009.409

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  35 in total

1.  Duodenal stenting for malignant gastric outlet obstruction: prospective study.

Authors:  Eduardo Guimarães Hourneaux Moura; Flávio Coelho Ferreira; Spencer Cheng; Diogo Turiani Hourneaux Moura; Paulo Sakai; Bruno Zilberstain
Journal:  World J Gastroenterol       Date:  2012-03-07       Impact factor: 5.742

2.  Endoscopy: Nitinol self-expanding metal stents--safe and effective?

Authors:  Rahul Pannala; Andrew S Ross
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2011-12-06       Impact factor: 46.802

3.  Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

Authors:  Chan Gyoo Kim; Il Ju Choi; Jong Yeul Lee; Soo-Jeong Cho; Soo Jin Kim; Mi-Jung Kim; Sook Ryun Park; Young Lee Park
Journal:  Surg Endosc       Date:  2013-09-12       Impact factor: 4.584

4.  Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

Authors:  Ji Won Kim; Ji Bong Jeong; Kook Lae Lee; Byeong Gwan Kim; Dong Won Ahn; Jae Kyung Lee; Su Hwan Kim
Journal:  World J Gastroenterol       Date:  2015-02-07       Impact factor: 5.742

Review 5.  Recent advancements in stent therapy in patients with malignant gastroduodenal outlet obstruction.

Authors:  Hironari Kato; Koichiro Tsutsumi; Hiroyuki Okada
Journal:  Ann Transl Med       Date:  2017-04

6.  Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

Authors:  Yasuki Hori; Itaru Naitoh; Kazuki Hayashi; Tesshin Ban; Makoto Natsume; Fumihiro Okumura; Takahiro Nakazawa; Hiroki Takada; Atsuyuki Hirano; Naruomi Jinno; Shozo Togawa; Tomoaki Ando; Hiromi Kataoka; Takashi Joh
Journal:  Surg Endosc       Date:  2017-03-09       Impact factor: 4.584

7.  Metallic Stent Expansion Rate at Day One Predicts Stent Patency in Patients with Gastric Outlet Obstruction.

Authors:  Bing-Wei Ye; Chung-Kai Chou; Yun-Cheng Hsieh; Chung-Pin Li; Yee Chao; Ming-Chih Hou; Han-Chieh Lin; Kuei-Chuan Lee
Journal:  Dig Dis Sci       Date:  2017-03-17       Impact factor: 3.199

8.  Enteral stents are safe and effective to relieve malignant gastric outlet obstruction in the elderly.

Authors:  Hala Mansoor; Faisal Zeb
Journal:  J Gastrointest Cancer       Date:  2015-03

9.  Self-expandable metallic stent placement in the palliative treatment of malignant obstruction of gastric outlet and duodenum.

Authors:  Erkan Caglar; Ahmet Dobrucali
Journal:  Clin Endosc       Date:  2013-01-31

10.  Endosonography-guided biliary drainage with one-step placement of a newly developed fully covered metal stent followed by duodenal stenting for pancreatic head cancer.

Authors:  Kei Ito; Naotaka Fujita; Yutaka Noda; Go Kobayashi; Takashi Obana; Jun Horaguchi; Shinsuke Koshita; Yoshihide Kanno; Takahisa Ogawa; Yuhei Kato; Yasunobu Yamashita
Journal:  Diagn Ther Endosc       Date:  2010-10-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.