Literature DB >> 19706572

A comparison of respiratory patterns in healthy term infants placed in car safety seats and beds.

Lilijana Kornhauser Cerar1, Christina V Scirica, Irena Stucin Gantar, Damjan Osredkar, David Neubauer, T Bernard Kinane.   

Abstract

OBJECTIVE: The purpose of this work was to compare the incidence of apnea, hypopnea, bradycardia, or oxygen desaturation in healthy term newborns placed in hospital cribs, infant car safety beds, or infant car safety seats.
METHODS: A consecutive series of 200 newborns was recruited on the second day of life. Each subject was studied while placed in the hospital crib (30 minutes), car bed (60 minutes), and car seat (60 minutes). Physiologic data, including oxygen saturation, frequency, and type of apnea, hypopnea, and bradycardia were obtained and analyzed in a blinded manner.
RESULTS: The mean oxygen saturation level was significantly different among all of the positions (97.9% for the hospital crib, 96.3% for the car bed, and 95.7% for the car seat; P < .001). The mean minimal oxygen saturation level was lower while in both safety devices (83.7% for the car bed and 83.6% for the car seat) compared with in the hospital crib (87.4%) (P < .001). The mean total time spent with an oxygen saturation level of <95% was significantly higher (P = .003) in both safety devices (car seat: 23.9%; car bed: 17.2%) when compared with the hospital crib (6.5%). A second study of 50 subjects in which each infant was placed in each position for 120 minutes yielded similar results.
CONCLUSIONS: In healthy term newborns, significant desaturations were observed in both car beds and car seats as compared with hospital cribs. This study was limited by lack of documentation of sleep stage. Therefore, these safety devices should only be used for protection during travel and not as replacements for cribs.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19706572     DOI: 10.1542/peds.2009-0160

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  6 in total

Review 1.  Screening for cardiopulmonary events in neonates: a review of the infant car seat challenge.

Authors:  N L Davis
Journal:  J Perinatol       Date:  2015-02-12       Impact factor: 2.521

2.  Exploring infant hip position and muscle activity in common baby gear and orthopedic devices.

Authors:  Safeer F Siddicky; Junsig Wang; Brien Rabenhorst; Lauren Buchele; Erin M Mannen
Journal:  J Orthop Res       Date:  2020-07-31       Impact factor: 3.494

3.  Car Seat Tolerance Screening in the Neonatal Intensive Care Unit: Failure Rates, Risk Factors, and Adverse Outcomes.

Authors:  Erik A Jensen; Elizabeth E Foglia; Kevin C Dysart; Zubair H Aghai; Alison Cook; Jay S Greenspan; Sara B DeMauro
Journal:  J Pediatr       Date:  2017-12-18       Impact factor: 4.406

4.  Positioning and baby devices impact infant spinal muscle activity.

Authors:  Safeer F Siddicky; David B Bumpass; Akshay Krishnan; Stewart A Tackett; Richard E McCarthy; Erin M Mannen
Journal:  J Biomech       Date:  2020-03-09       Impact factor: 2.712

5.  Post-sedation events in children sedated for dental care.

Authors:  Priyanshi Ritwik; Linda T Cao; Ronald Curran; Robert J Musselman
Journal:  Anesth Prog       Date:  2013

6.  Cervical collars and immobilisation: A South African best practice recommendation.

Authors:  D Stanton; T Hardcastle; D Muhlbauer; D van Zyl
Journal:  Afr J Emerg Med       Date:  2017-01-28
  6 in total