Force decay of elastomeric ligatures: influence on unloading force compared to self-ligation.

Alan Petersen1, Sheldon Rosenstein, Ki Beom Kim, Heidi Israel.   

Abstract

OBJECTIVE: To compare elastomeric ligatures (EL) vs self-ligating (SL) brackets in terms of their effects on the unloading force of a 0.014-inch CuNiTi aligning wire.
MATERIALS AND METHODS: By simulating the alignment of a lingually malposed canine and using a full-arch design, three ligation methods -- SL, EL, and "relaxed" elastomeric ligature (REL) -- were tested with 30 wires per group. Each test was conducted in a dry field within a Plexiglas case at 35 +/- 2 degrees C. Eleven brackets were affixed from first molar to first molar site on a steel plate with a space created at the location of the left canine. The wire was deflected 3 mm then was unloaded at a speed of 2 mm per minute. Data were gathered from four points along the unloading plot generated during each test and then were compared by using the Kruskal-Wallis one-way analysis of variance. Mann-Whitney tests were used to compare combinations of groups.
RESULTS: Wires ligated with EL and REL produced an average unloading force equal to 56% and 88%, respectively, of the same wire in an SL bracket.
CONCLUSIONS: The unloading forces produced by a wire after force decay of the elastomers are not statistically different from the forces present in self-ligating systems.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19705929     DOI: 10.2319/070208-338.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  An indigenously designed apparatus for measuring orthodontic force.

Authors:  S P Saravana Dinesh; A V Arun; K K Shantha Sundari; Christine Samantha; K Ambika
Journal:  J Clin Diagn Res       Date:  2013-10-24

2.  Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations.

Authors:  Riccardo Nucera; Elda Gatto; Chiara Borsellino; Pasquale Aceto; Francesca Fabiano; Giovanni Matarese; Letizia Perillo; Giancarlo Cordasco
Journal:  Angle Orthod       Date:  2013-09-25       Impact factor: 2.079

3.  Evaluation of the effect of different stretching patterns on force decay and tensile properties of elastomeric ligatures.

Authors:  Amin Aminian; Samaneh Nakhaei; Raha Habib Agahi; Masoud Rezaeizade; Hamed Mirzazadeh Aliabadi; Majid Heidarpour
Journal:  Dent Res J (Isfahan)       Date:  2015 Nov-Dec

4.  Force level of small diameter nickel-titanium orthodontic wires ligated with different methods.

Authors:  Rodrigo Hitoshi Higa; José Fernando Castanha Henriques; Guilherme Janson; Murilo Matias; Karina Maria Salvatore de Freitas; Fernanda Pinelli Henriques; Manoela Fávaro Francisconi
Journal:  Prog Orthod       Date:  2017-08-01       Impact factor: 2.750

5.  Discoloration and force degradation of orthodontic elastomeric ligatures.

Authors:  Samaneh Nakhaei; Raha Habib Agahi; Amin Aminian; Masoud Rezaeizadeh
Journal:  Dental Press J Orthod       Date:  2017 Mar-Apr

6.  Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure.

Authors:  Aneta Olszewska; Anetta Hanć; Danuta Barałkiewicz; Piotr Rzymski
Journal:  Biol Trace Elem Res       Date:  2019-11-04       Impact factor: 3.738