Literature DB >> 19702681

Marginal bone loss around three different implant systems: radiographic evaluation after 1 year.

C M Piao1, J E Lee, J Y Koak, S K Kim, I C Rhyu, C H Han, Y Herr, S J Heo.   

Abstract

This study was designed to radiographically evaluate the effect of surface macro-and microstructures within the coronal portion of the external hex implant at the marginal bone change after loading. The fifty-four patients included in the study were randomly assigned to treatment groups with rough-surface implants (TiUnite, n = 45), a hybrid of smooth and rough surface implants (Restore, n = 45) or rough-surface with microthreads implants (Hexplant, n = 45). Clinical and radiographic examinations were conducted at the time of implant loading (baseline) and at 1-year post-loading. A three-level mixed-effect ancova was used to test the significance of the mean marginal bone change of the three implant groups from baseline to 1-year follow-up. At 1-year, significant differences were noted in marginal bone loss recorded for the three groups (P < 0.0001). The rough surface with microthread implants had a mean crestal bone loss of 0.42 +/- 0.27 mm; the rough surface implants, 0.81 +/- 0.27 mm; and the hybrid surface implants, 0.89 +/- 0.41 mm. Within the limitations of this study, a rough surface with microthreads at the coronal part of implant maintained the marginal bone level against functional loading better than implants without these two features.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19702681     DOI: 10.1111/j.1365-2842.2009.01988.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  11 in total

1.  Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view.

Authors:  K Kamburoğlu; S Murat; C Kılıç; S Yüksel; H Avsever; A Farman; W C Scarfe
Journal:  Dentomaxillofac Radiol       Date:  2014-03-20       Impact factor: 2.419

2.  Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading.

Authors:  Aar Rasouli Ghahroudi; Ar Talaeepour; A Mesgarzadeh; Ar Rokn; A Khorsand; Nn Mesgarzadeh; Mj Kharazi Fard
Journal:  J Dent (Tehran)       Date:  2010-06-30

Review 3.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

Review 4.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

5.  Complications During Maxillary Sinus Augmentation Associated with Interfering Septa: A New Classification of Septa.

Authors:  Tassos Irinakis; Valentin Dabuleanu; Salwa Aldahlawi
Journal:  Open Dent J       Date:  2017-03-22

6.  Influence of Implant Neck Design on Crestal Bone Loss: A Comparative Study.

Authors:  Yojana B Patil; Swati Joshi Asopa; Aashana Goel; Divya Jyoti; Nagaveni S Somayaji; Robin Sabharwal
Journal:  Niger J Surg       Date:  2020-02-10

Review 7.  Influence of marginal bone loss on peri-implantitis: Systematic review of literature.

Authors:  Alba Carrasco-García; Lizett Castellanos-Cosano; José-Ramon Corcuera-Flores; Antonio Rodríguez-Pérez; Daniel Torres-Lagares; Guillermo Machuca-Portillo
Journal:  J Clin Exp Dent       Date:  2019-11-01

Review 8.  Effect of laser-microtexturing on bone and soft tissue attachments to dental implants: A systematic review and meta-analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

9.  A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

Authors:  Antoine N Berberi; Joseph M Sabbagh; Moustafa N Aboushelib; Ziad F Noujeim; Ziad A Salameh
Journal:  Front Physiol       Date:  2014-01-31       Impact factor: 4.566

10.  Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Part I: Hard Tissues.

Authors:  Rubén Agustín-Panadero; Naia Bustamante-Hernández; María Fernanda Solá-Ruíz; Álvaro Zubizarreta-Macho; Antonio Fons-Font; Lucía Fernández-Estevan
Journal:  J Clin Med       Date:  2019-12-11       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.