Literature DB >> 19699396

A novel microextraction technique based on 1-hexylpyridinium hexafluorophosphate ionic liquid for the preconcentration of zinc in water and milk samples.

H Abdolmohammad-Zadeh1, G H Sadeghi.   

Abstract

A simple dispersive liquid-liquid microextraction methodology based on the application of 1-hexylpyridinium hexafluorophosphate [HPy][PF6] ionic liquid (IL) as an extractant solvent was proposed for the preconcentration of trace levels of zinc as a prior step to determination by flame atomic absorption spectrometry (FAAS). Zinc was complexed with 8-hydroxyquinoline (oxine) and extracted into ionic liquid. Some effective factors that influence the microextraction efficiency such as pH, oxine concentration, amount of IL, ionic strength, temperature and centrifugation time were investigated and optimized. In the optimum experimental conditions, the limit of detection (3 s) and the enhancement factor were 0.22 microg L(-1) and 71, respectively. The relative standard deviation (RSD) for six replicate determinations of 13 microg L(-1) Zn was 1.92%. In order to validate the developed method, a certified reference material (NIST SRM 1549) was analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the trace determination of zinc in water and milk samples.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19699396     DOI: 10.1016/j.aca.2009.07.040

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

Authors:  Sadaf S Arain; Tasneem G Kazi; Asma J Arain; Hassan I Afridi; Muhammad B Arain; Kapil D Brahman; Abdul H Panhwar; Mariam S Arain
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-23       Impact factor: 4.223

2.  Ultrasound-assisted ionic liquid-based microextraction combined with least squares support vector machines regression for the simultaneous determination of aluminum, gallium, and indium in water and coal samples.

Authors:  Jahan B Ghasemi; Ehsan Zolfonoun
Journal:  Environ Monit Assess       Date:  2011-07-27       Impact factor: 2.513

3.  Determination of Trace Antimony (III) in Water Samples with Single Drop Microextraction Using BPHA-[C4mim][PF6] System Followed by Graphite Furnace Atomic Absorption Spectrometry.

Authors:  Xiaoshan Huang; Mingxin Guan; Zhuliangzi Lu; Yiping Hang
Journal:  Int J Anal Chem       Date:  2018-08-01       Impact factor: 1.885

Review 4.  Recent applications of ionic liquids in separation technology.

Authors:  Dandan Han; Kyung Ho Row
Journal:  Molecules       Date:  2010-04-05       Impact factor: 4.411

5.  Fluorescent bioassays for toxic metals in milk and yoghurt.

Authors:  Mohammad Shohel Rana Siddiki; Shunsaku Ueda; Isamu Maeda
Journal:  BMC Biotechnol       Date:  2012-10-25       Impact factor: 2.563

Review 6.  Green Approaches to Sample Preparation Based on Extraction Techniques.

Authors:  Alshymaa A Aly; Tadeusz Górecki
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.