Literature DB >> 19689726

Hardness of three resin-modified glass-ionomer restorative materials as a function of depth and time.

Howard W Roberts1, David W Berzins, David G Charlton.   

Abstract

STATEMENT OF THE PROBLEM: The polymerization of bulk-placed resin-modified glass-ionomer (RMGI) restoratives is compromised when penetration of the curing light is limited because of the materials' thickness. It is unknown if additional post light-curing resin polymerization and/or glass-ionomer setting occurs over time to ensure adequate polymerization.
PURPOSE: The primary objective was to evaluate the depth of cure of various thicknesses of RMGI restorative products over 1 year using Knoop hardness (KH) testing.
MATERIALS AND METHODS: The materials were placed in Delrin molds having an internal diameter of 5.0 mm and heights of 2, 3, 4, and 5 mm and were photopolymerized with a halogen light-curing unit. Five specimens of each depth were prepared for each time period evaluated. Specimens were stored in darkness at 37 +/- 2 degrees C and 98 +/- 2% humidity until being tested at 24 hours, 1 week, and 1, 3, 6, 9, and 12 months after fabrication. Mean KH values were calculated for the bottom and top surfaces of each thickness group and used to determine bottom/top hardness ratios. Data were compared using two-way analysis of variance (factors of time, thickness) at a 0.05 significance level with Scheffé's post hoc analysis, where required.
RESULTS: The materials had relatively stable top surface KH, which permitted valid assessment of changes in bottom surface KH over time. The bottom surface KH of some RMGIs changed significantly over time (p < 0.001), but degrees of change were material dependent. Certain RMGIs demonstrated a potential for statistically significant post light-activation hardening; however, that too was material dependent. As compared with top surface KH, deeper layers of the thicker RMGI specimens consistently failed to achieve an adequate degree of polymerization.
CONCLUSION: Although certain RMGI materials demonstrate a potential for post light-activation chemically initiated resin polymerization and/or polyalkenoate acid/base reaction, these reactions may not be sufficient to ensure that the material is adequately polymerized for long-term success. This is particularly true when RMGI materials are placed in thicker layers where curing light penetration may be compromised. CLINICAL SIGNIFICANCE: RMGI materials should not be placed in bulk but photopolymerized in layers to ensure adequate light activation. The results of this study suggest that Photac-Fil Quick be placed in layers no thicker than 2 mm while Fuji II LC and Vitremer may be placed in layers up to 3 mm in thickness.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19689726     DOI: 10.1111/j.1708-8240.2009.00273.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  8 in total

1.  Effect of Saliva Contamination on Microleakage of Open Sandwich Restorations.

Authors:  Çiğdem Çelik; Yusuf Bayraktar; Behiye Esra Özdemir
Journal:  Acta Stomatol Croat       Date:  2020-09

2.  Influence of photoactivation source on restorative materials and enamel demineralization.

Authors:  Josiane Marques de Sena Popoff; José Augusto Rodrigues; Wanessa Maria De Freitas Aras; Alessandra Cassoni
Journal:  Photomed Laser Surg       Date:  2014-04-07       Impact factor: 2.796

3.  Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites.

Authors:  Riccardo Monterubbianesi; Giovanna Orsini; Giorgio Tosi; Carla Conti; Vito Librando; Maurizio Procaccini; Angelo Putignano
Journal:  Front Physiol       Date:  2016-12-27       Impact factor: 4.566

4.  Effects of Curing Modes on the Microhardness of Resin-modified Glass Ionomer Cements.

Authors:  Jelena Spajic; Matej Par; Ognjen Milat; Nazif Demoli; Ruza Bjelovucic; Katica Prskalo
Journal:  Acta Stomatol Croat       Date:  2019-03

5.  Bond strength and elemental analysis of oxidized dentin bonded to resin modified glass ionomer based restorative material.

Authors:  Youssef-Abdullah Al-Gerny; Sayed-Mohammed Ghorab; Tarek-Ahmed Soliman
Journal:  J Clin Exp Dent       Date:  2019-03-01

6.  How Can Different Polishing Timing Influence Methacrylate and Dimethacrylate Bulk Fill Composites? Evaluation of Chemical and Physical Properties.

Authors:  Riccardo Monterubbianesi; Vincenzo Tosco; Simona Sabbatini; Giulia Orilisi; Carla Conti; Mutlu Özcan; Giovanna Orsini; Angelo Putignano
Journal:  Biomed Res Int       Date:  2020-01-09       Impact factor: 3.411

7.  Effects of surface coating on the flexural strength of fluoridereleasing restorative materials after water aging for one year.

Authors:  Muhittin Ugurlu
Journal:  Eur Oral Res       Date:  2020-05-01

8.  Effect of resin thickness, and curing time on the micro-hardness of bulk-fill resin composites.

Authors:  Shaymaa M Nagi; Lamiaa M Moharam; Mohamed H Zaazou
Journal:  J Clin Exp Dent       Date:  2015-12-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.