Literature DB >> 19686615

Reading the small print - labelling recommendations for orthopaedic implants.

Roger A Haene1, Ranbir S Sandhu, Richard Baxandall.   

Abstract

INTRODUCTION: There exist, currently, no clear guidelines regarding standards for surgical implant labelling. Dimensions of the laminar flow canopies in orthopaedic use fixes the distance at which implant labels can be read. Mistakes when reading the label on an implant box can pose health risks for patients, and financial consequences for medical institutions. SUBJECTS AND METHODS: Using scientifically validated tools such as the Snellen Chart Formula, a theoretical minimum standard for text on implant labels was reached. This theoretical standard was then tested under real operating conditions. After discovering a minimum practical standard for implant labels, the authors then audited current labels in use on a wide range of orthopaedic implant packages. Furthermore, other non-text-related labelling problems were also noted.
RESULTS: There is a definite minimum standard which should be observed when implant labels are manufactured. Implants in current use bear labels on the packaging that are of an insufficient standard to ensure patient safety in theatre.
CONCLUSIONS: The authors have established text parameters that will increase the legibility of implant labels. In the interests of improving risk management in theatre, therefore, the authors propose a standard for orthopaedic implant labelling, and believe this will provide a useful foundation for further discussion between the orthopaedic community and implant manufacturers.

Entities:  

Mesh:

Year:  2009        PMID: 19686615      PMCID: PMC2966240          DOI: 10.1308/003588409X432392

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  12 in total

1.  How crowding affects letter confusion.

Authors:  L Liu; A Arditi
Journal:  Optom Vis Sci       Date:  2001-01       Impact factor: 1.973

2.  Interaction between aberrations to improve or reduce visual performance.

Authors:  Raymond A Applegate; Jason D Marsack; Roberto Ramos; Edwin J Sarver
Journal:  J Cataract Refract Surg       Date:  2003-08       Impact factor: 3.351

3.  Visual neuroscience before the neuron.

Authors:  Nicholas J Wade
Journal:  Perception       Date:  2004       Impact factor: 1.490

4.  Clothing in laminar-flow operating theatres.

Authors:  M J Hubble; A E Weale; J V Perez; K E Bowker; A P MacGowan; G C Bannister
Journal:  J Hosp Infect       Date:  1996-01       Impact factor: 3.926

5.  Binocular vision recovery in bilateral keratoplasty.

Authors:  R Sampaio; E Held; E J Cohen; S Grewal; C J Rapuano; A F Smith; P R Laibson
Journal:  Cornea       Date:  2001-07       Impact factor: 2.651

6.  Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint. With special reference to the bacterial content of the air of the operating room.

Authors:  J Charnley; N Eftekhar
Journal:  Br J Surg       Date:  1969-09       Impact factor: 6.939

7.  Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system.

Authors:  E A Salvati; R P Robinson; S M Zeno; B L Koslin; B D Brause; P D Wilson
Journal:  J Bone Joint Surg Am       Date:  1982-04       Impact factor: 5.284

Review 8.  Air, antibiotics and sepsis in replacement joints.

Authors:  O M Lidwell
Journal:  J Hosp Infect       Date:  1988-05       Impact factor: 3.926

9.  Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.

Authors:  O M Lidwell; E J Lowbury; W Whyte; R Blowers; S J Stanley; D Lowe
Journal:  Br Med J (Clin Res Ed)       Date:  1982-07-03

10.  Considering the impact of medicine label design characteristics on patient safety.

Authors:  E Hellier; J Edworthy; N Derbyshire; A Costello
Journal:  Ergonomics       Date:  2006 Apr 15-May 15       Impact factor: 2.778

View more