Literature DB >> 19683935

Removal of a foreign body from the skull base using a customized computer-designed guide bar.

Ran Wei1, Liu Xiang-Zhen, Guo Bing, Shu Da-Long, Tan Ze-Ming.   

Abstract

BACKGROUND: Foreign bodies located at the base of the skull pose a surgical challenge. Here, a customized computer-designed surgical guide bar was designed to facilitate removal of a skull base foreign body.
METHODS: Within 24h of the patient's presentation, a guide bar and mounting platform were designed to remove a foreign body located adjacent to the transverse process of the atlas and pressing against the internal carotid artery.
RESULTS: The foreign body was successfully located and removed using the custom designed guide bar and computer operative planning. Ten months postoperatively the patient was free of complaints and lacked any complications such as restricted opening of the mouth or false aneurysm. The inferior alveolar nerve damage noted immediately postoperatively (a consequence of mandibular osteotomy) was slightly reduced at follow-up, but labial numbness persisted.
CONCLUSIONS: The navigation tools described herein were successfully employed to aid foreign body removal from the skull base. Copyright (c) 2009 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19683935     DOI: 10.1016/j.jcms.2009.07.006

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  8 in total

Review 1.  Automating the processing steps for obtaining bone tissue-engineered substitutes: from imaging tools to bioreactors.

Authors:  Pedro F Costa; Albino Martins; Nuno M Neves; Manuela E Gomes; Rui L Reis
Journal:  Tissue Eng Part B Rev       Date:  2014-07-31       Impact factor: 6.389

2.  A novel navigation system to guide metallic foreign body extraction.

Authors:  Bin He; Chao Xu; Yingdelong Mao; Jingwen Mao; Liping Shen; Hao Wei; Fei Wang; Shuogui Xu
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-27       Impact factor: 2.924

3.  Accuracy of half-way mucosa-supported implant guides for edentulous jaws: a retrospective study with a median follow-up of 2 years.

Authors:  Weiwei Tang; Qilong Liu; Xianshang Zeng; Jiali Yu; Dalong Shu; Guorong Shen; Weiguang Yu; Xiangzhen Liu; Guixing Xu
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

4.  Successful Localization of Intraoral Foreign Body with C-arm Fluoroscopy.

Authors:  Young-Hoon Kang; June-Ho Byun; Mun-Jeong Choi; Bong-Wook Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2014-09-30

5.  Accuracy of using computer-aided rapid prototyping templates for mandible reconstruction with an iliac crest graft.

Authors:  Da-long Shu; Xiang-zhen Liu; Bing Guo; Wei Ran; Xin Liao; Yun-yan Zhang
Journal:  World J Surg Oncol       Date:  2014-06-24       Impact factor: 2.754

Review 6.  Application of computer-assisted navigation systems in oral and maxillofacial surgery.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Yoshihiko Furuki
Journal:  Jpn Dent Sci Rev       Date:  2018-05-07

7.  Comparison of the efficacy and characteristics of metallic foreign body extraction by incision surgery and x-ray guided forceps after body-surface projection positioning: A STROBE-compliant article.

Authors:  Hexiang Qian; Xianju Qin; Guangfu Xing; Changwen Shi; Li Zhang
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

8.  Role of Navigation in Oral and Maxillofacial Surgery: A Surgeon's Perspectives.

Authors:  Manish Anand; Shreya Panwar
Journal:  Clin Cosmet Investig Dent       Date:  2021-04-15
  8 in total