Literature DB >> 19683889

Three-phase, liquid-phase microextraction combined with high performance liquid chromatography-fluorescence detection for the simultaneous determination of fluoxetine and norfluoxetine in human plasma.

Daniela Fernanda de Freitas1, Carlos Eduardo Dobrovolskin Porto, Elisabeth Pizzamiglio Vieira, Maria Elisa Pereira Bastos de Siqueira.   

Abstract

A three-phase, liquid-phase microextraction using a hollow fibre (HF-LPME) combined with high performance liquid chromatography-fluorescence detection (HPLC-FL) was developed for the analysis of fluoxetine (FLX) and its active metabolite, norfluoxetine (NFLX), in human plasma. An HF-LPME system using a disposable 7-cm polypropylene porous hollow fibre, 5 mL of alkaline plasma solution (donor phase), n-hexyl ether (extraction solvent) and 20 mM hydrochloric acid (acceptor phase) was used in the extraction. The method was validated after optimisation of several parameters that influence LPME efficiency. A reverse-phase LiChrospher 60 RP-Select B column (125 mm x 4 mm, 5 microm particle size) was used with 0.005 M sodium acetate buffer (pH 4.5) and acetonitrile at a 50:50 (v/v) as the mobile phase at a flow rate of 0.6 mL min(-1). In these conditions satisfactory chromatographic resolution and efficiency for the analytes were obtained. Fluorescence detection at 230 nm excitation wavelength and 290 nm emission wavelength was performed. Linearity over a range of 5-500 ng mL(-1), with determination coefficients (R(2)) of 0.9999 and 0.9962 for FLX and NFLX, respectively, was established. Venlafaxine was used as the internal standard for both analytes. Extraction recoveries from plasma samples were 70.9% for FLX and 59.7% for NFLX. The intra-day coefficients of variation (CVs) were below 5.4%, and inter-day CVs were below 13.0%, for both analytes at concentrations of 20, 80 and 160 ng mL(-1). HF-LPME extraction followed by HPLC-FL detection for FLX and NFLX analyses demonstrated excellent sample clean-up and selectivity. This method was simple, cheap, and easy to perform, yielding substantial analytes enrichment. The method was applied to the analysis of samples from 12 patients under fluoxetine treatment and proved suitable for routine therapeutic drug monitoring for this antidepressant.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19683889     DOI: 10.1016/j.jpba.2009.07.017

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Development of a dispersive liquid-liquid microextraction technique for the extraction and spectrofluorimetric determination of fluoxetine in pharmaceutical formulations and human urine.

Authors:  Ahad Bavili Tabrizi; Ahmad Rezazadeh
Journal:  Adv Pharm Bull       Date:  2012-06-15

Review 2.  Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology.

Authors:  Vahid Sharifi; Ali Abbasi; Anahita Nosrati
Journal:  J Food Drug Anal       Date:  2016-01-07       Impact factor: 6.157

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.