Comparability of a hand-held nitric oxide analyser with online and offline chemiluminescence-based nitric oxide measurement.

Barbara Schiller1, Juerg Hammer, Juerg Barben, Daniel Trachsel.   

Abstract

Practicability is crucial for successful implementation of fractional exhaled nitric oxide (FeNO) measurement into asthma management. The study aimed at comparing a conventional chemiluminescence NO analyser (EcoMedics) with a hand-held device (NIOX MINO) and offline FeNO measurement using a commercially available system in an unselected cohort of children aged 6-16 yr. A secondary objective was to confirm FeNO stability over time in 15 samples from adult volunteers obtained using the offline system. Sixty-six children (mean +/- s.d. age 11.8 +/- 3.0 yr) underwent single breath FeNO measurement in triplets with each device. Offline collected FeNO was measured after offline breath collection into a Mylar balloon and subsequent analysis using the chemiluminescence NO analyser. Variability and between-method agreement were assessed, and stability over time within the Mylar balloons was tested by repeated hourly measurements. FeNO levels ranged from 2 to 113 p.p.b. Intra-class correlation was excellent (r = 0.98, p < 0.001 for each pair). Bland-Altman plots and back-transformation of logarithmic mean differences revealed fair agreement between methods. Stability over time was confirmed over 10 h both at room temperature and when stored under cooling conditions. FeNO values obtained using the chemiluminescence NO analyser, the portable NIOX MINO system and the offline collection technique show between-method agreement within clinically acceptable range.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19682277     DOI: 10.1111/j.1399-3038.2009.00853.x

Source DB:  PubMed          Journal:  Pediatr Allergy Immunol        ISSN: 0905-6157            Impact factor:   6.377


  9 in total

Review 1.  Noninvasive effects measurements for air pollution human studies: methods, analysis, and implications.

Authors:  Jaime Mirowsky; Terry Gordon
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-01-21       Impact factor: 5.563

Review 2.  An Evidence-Based Review of Application Devices for Nitric Oxide Concentration Determination from Exhaled Air in the Diagnosis of Inflammation and Treatment Monitoring.

Authors:  Magdalena Wyszyńska; Monika Nitsze-Wierzba; Aleksandra Czelakowska; Jacek Kasperski; Joanna Żywiec; Małgorzata Skucha-Nowak
Journal:  Molecules       Date:  2022-07-03       Impact factor: 4.927

3.  Guideline-recommended fractional exhaled nitric oxide is a poor predictor of health-care use among inner-city children and adolescents receiving usual asthma care.

Authors:  Meredith C McCormack; Charles Aloe; Jean Curtin-Brosnan; Gregory B Diette; Patrick N Breysse; Elizabeth C Matsui
Journal:  Chest       Date:  2013-09       Impact factor: 9.410

4.  Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

Authors:  Amanda Harris; Esther Bhullar; Kerry Gove; Rhiannon Joslin; Jennifer Pelling; Hazel J Evans; Woolf T Walker; Jane S Lucas
Journal:  BMC Pulm Med       Date:  2014-02-10       Impact factor: 3.317

5.  Clinical Utility Of The Exhaled Nitric Oxide (NO) Measurement With Portable Devices In The Management Of Allergic Airway Inflammation And Asthma.

Authors:  Sy Duong-Quy
Journal:  J Asthma Allergy       Date:  2019-10-07

6.  Pilot Study of Use of Nitric Oxide in Monitoring Multiple Dental Foci in Oral Cavity-A Case Report.

Authors:  Magdalena Wyszyńska; Przemysław Rosak; Aleksandra Czelakowska; Ewa Białożyt-Bujak; Jacek Kasperski; Maciej Łopaciński; Nour Al Khatib; Małgorzata Skucha-Nowak
Journal:  Healthcare (Basel)       Date:  2022-01-20

7.  Effect of mannitol dry powder challenge on exhaled nitric oxide in children.

Authors:  Juerg Barben; Marie-Pierre F Strippoli; Daniel Trachsel; Barbara Schiller; Juerg Hammer; Claudia E Kuehni
Journal:  PLoS One       Date:  2013-01-18       Impact factor: 3.240

8.  Associations of short-term particle and noise exposures with markers of cardiovascular and respiratory health among highway maintenance workers.

Authors:  Reto Meier; Wayne E Cascio; Andrew J Ghio; Pascal Wild; Brigitta Danuser; Michael Riediker
Journal:  Environ Health Perspect       Date:  2014-03-19       Impact factor: 9.031

Review 9.  Fractional exhaled nitric oxide-measuring devices: technology update.

Authors:  Mauro Maniscalco; Carolina Vitale; Alessandro Vatrella; Antonio Molino; Andrea Bianco; Gennaro Mazzarella
Journal:  Med Devices (Auckl)       Date:  2016-06-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.