Literature DB >> 19679641

Long-term follow-up of 1036 cerebral aneurysms treated by bare coils: a multicentric cohort treated between 1998 and 2003.

S Gallas1, A C Januel, A Pasco, J Drouineau, J Gabrillargues, A Gaston, C Cognard, D Herbreteau.   

Abstract

BACKGROUND AND
PURPOSE: The endovascular treatment (EVT) of cerebral aneurysms has experienced a revolution since 1991 with the introduction of platinum coil technology. During the past 10 years, there has been significant study of the feasibility of this technique, and clinical results of EVT have been published. The long-term durability of Guglielmi detachable coil (GDC) embolization of cerebral aneurysms still remains unknown. The purpose of this study was to evaluate the stability of anatomic occlusion of aneurysms and to assess the rate of recanalization and retreatment of these aneurysms.
MATERIALS AND METHODS: Between January 1998 and December 2003, 1036 aneurysms (804 ruptured and 232 nonruptured) were treated consecutively with GDC coils in 5 neuroradiology centers. Procedural feasibility, acute angiographic occlusion results, morbidity, and mortality associated with this technique were assessed. All patients were regularly followed by digital subtraction angiography and MR imaging each year after treatment.
RESULTS: Initial acute angiographic results in 1036 aneurysms demonstrated total occlusion in 731 patients (70.5%), subtotal occlusion in 252 (24.3%), incomplete occlusion in 20 (1.9%), and failures in 33% (3.3%) aneurysms. A remodeling technique was used in 10%. A second procedure was performed for 72 aneurysms (7%). The total aneurysm follow-up time was 49,923 months (4160.25 aneurysm-years). The retreatment period was either in the months following initial treatment in aneurysms incompletely occluded or in years due to recanalization or de novo aneurysms. Fewer than 5 patients rebled during 10 years of follow-up. Long-term follow-up angiograms were obtained in 899 aneurysms, with 646 total, 230 subtotal, and 23 incomplete results.
CONCLUSIONS: Long-term follow-up of cerebral aneurysms is necessary to depict recanalization. Only 7% of the aneurysms were retreated. Use of bare coils gives a good long-term level of occlusion.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19679641     DOI: 10.3174/ajnr.A1744

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  38 in total

Review 1.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

2.  Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Osamu Ikeda; Yoshitaka Tamura; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Takayuki Kawano; Toshinori Hirai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-08-14       Impact factor: 5.315

3.  The place for remodeling technique and stenting in the endovascular management of intracranial aneurysms: a single-center analysis from 2008 to 2010.

Authors:  Laurent Pierot; Girish Rajpal; Krzysztof Kadziolka; Coralie Barbe
Journal:  Neuroradiology       Date:  2011-11-09       Impact factor: 2.804

4.  Long-term follow-up study of endovascularly treated intracranial aneurysms.

Authors:  L M Pyysalo; L H Keski-Nisula; T T Niskakangas; V J Kähärä; J E Ohman
Journal:  Interv Neuroradiol       Date:  2010-10-25       Impact factor: 1.610

Review 5.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

Review 6.  Review of 2 decades of aneurysm-recurrence literature, part 2: Managing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

7.  Endovascular treatment of recurrent coiled aneurysms: assessment of complications and rebleeding during a decade in a single center.

Authors:  J Sedat; Y Chau; K Moubarak; J Vargas; M Lonjon
Journal:  Interv Neuroradiol       Date:  2012-03-16       Impact factor: 1.610

8.  Five to ten years follow-up after coiling of 241 patients with acutely ruptured aneurysms. A single centre experience.

Authors:  A Consoli; L Renieri; R Mura; S Nappini; F Ricciardi; G Pecchioli; F Ammannati; S Mangiafico
Journal:  Interv Neuroradiol       Date:  2012-03-16       Impact factor: 1.610

9.  Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography.

Authors:  Masaki Katsura; Jiro Sato; Masaaki Akahane; Taku Tajima; Toshihiro Furuta; Harushi Mori; Osamu Abe
Journal:  Neuroradiology       Date:  2018-08-24       Impact factor: 2.804

10.  Hemodynamic Characteristics Regarding Recanalization of Completely Coiled Aneurysms: Computational Fluid Dynamic Analysis Using Virtual Models Comparison.

Authors:  Wonhyoung Park; Yunsun Song; Kye Jin Park; Hae-Won Koo; Kuhyun Yang; Dae Chul Suh
Journal:  Neurointervention       Date:  2016-03-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.