Literature DB >> 19678445

Influence of photoactivation protocol and light guide distance on conversion and microleakage of composite restorations.

N R G Fróes-Salgado1, C S C Pfeifer, C E Francci, Y Kawano.   

Abstract

PURPOSE: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. METHODS AND MATERIALS: Three photoactivation protocols (600 mW/cm2 x 40 seconds; 400 mW/cm2 x 60 seconds or 200 mW/cm2 x 20 seconds, followed by 500 mW/cm2 x 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 mm diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silver-nitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification.
RESULTS: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400 mW/cm2 that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source.
CONCLUSIONS: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19678445     DOI: 10.2341/08-104

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  4 in total

1.  Influence of irradiation distance on the mechanical performances of resin composites polymerized with high-irradiance light curing units.

Authors:  Soram Oh; Hyun Ju Kim; Hyun-Jung Kim; Sibel A Antonson; Sun-Young Kim
Journal:  Biomater Res       Date:  2022-05-20

2.  Effect of C-factor and LED Curing Mode on Microleakage of Class V Resin Composite Restorations.

Authors:  Qasem Diefallah Alomari; Kefah Barrieshi-Nusair; Mohammad Ali
Journal:  Eur J Dent       Date:  2011-08

3.  Microleakage of dual-cured adhesive systems in class v composite resin restorations.

Authors:  S Kasraie; M Azarsina; Z Khamverdi; F Shokraneh
Journal:  J Dent (Tehran)       Date:  2012-06-30

4.  Effect of operator variability on microleakage with different adhesive systems.

Authors:  Emel Karaman; A Ruya Yazici; Burak Aksoy; Erdem Karabulut; Gul Ozgunaltay; Berrin Dayangac
Journal:  Eur J Dent       Date:  2013-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.