Literature DB >> 19676149

Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes.

Jeffrey Chance1, Julie Berube, Marita Vandersmissen, Norbert Blanckaert.   

Abstract

BACKGROUND: The performance of the BD Vacutainer PST II Tube for testing of special chemistry analytes was evaluated in comparison to serum and heparin plasma non-gel blood collection tubes. The comparison tubes included the BD Vacutainer Serum Plus Tube, the BD Vacutainer Lithium Heparin Plus Tube, and the BD Vacutainer Lithium Heparin Glass Tube.
METHODS: Tubes were drawn by routine venipuncture from 42 subjects according to a randomized draw order. Tubes were processed and centrifuged according to recommended handling procedures. Serum and plasma from the comparison tubes were aliquoted to secondary containers prior to analysis. Specimens were then tested for selected special chemistry analytes at two time intervals (initial time and after 24 h storage). Analytes tested included thyroid stimulating hormone, free thyroxine, total thyroxine, follicle stimulating hormone, luteinizing hormone, ferritin, cortisol, vitamin B12, folate, and testosterone. The data were collected and analyzed by analysis of variance and mean bias comparisons.
RESULTS: The performance of the BD Vacutainer PST II Tube was considered to be clinically equivalent to all three comparison tubes for all assays. Test results from the BD Vacutainer PST II Tube and from aliquots from the three comparison tubes at 24 h were considered to be clinically equivalent to those at initial time for all assays.
CONCLUSIONS: The BD Vacutainer PST II Tube provided clinically equivalent results to serum and plasma non-gel tubes and good storage stability for the assays evaluated without the need to aliquot.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19676149     DOI: 10.1515/cclm.2009.072

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  Morin ameliorates the testicular apoptosis, oxidative stress, and impact on blood-testis barrier induced by photo-extracellularly synthesized silver nanoparticles.

Authors:  Ahmed Hamed Arisha; Mona M Ahmed; Mohamed A Kamel; Yasser A Attia; Mohamed M A Hussein
Journal:  Environ Sci Pollut Res Int       Date:  2019-08-02       Impact factor: 4.223

2.  Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.

Authors:  Marija Kocijancic; Jelena Cargonja; Alma Delic-Knezevic
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

3.  Abnormal gel flotation caused by contrast media during adrenal vein sampling.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Matteo Gelati; Antonella Bassi; Alberto Contro; Francesca Pizzolo; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2016-10-15       Impact factor: 2.313

4.  Comparison of Barricor™ vs. lithium heparin tubes for selected routine biochemical analytes and evaluation of post centrifugation stability.

Authors:  Anne Marie Dupuy; Stéphanie Badiou; Delphine Daubin; Anne Sophie Bargnoux; Chloé Magnan; Kadda Klouche; Jean Paul Cristol
Journal:  Biochem Med (Zagreb)       Date:  2018-04-15       Impact factor: 2.313

Review 5.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

6.  Chemotherapeutic Potential of Epimedium brevicornum Extract: The cGMP-Specific PDE5 Inhibitor as Anti-Infertility Agent Following Long-Term Administration of Tramadol in Male Rats.

Authors:  Ahmed S Abdelaziz; Mohamed A Kamel; Amany I Ahmed; Shimaa I Shalaby; Salama M El-Darier; Amany Magdy Beshbishy; Gaber El-Saber Batiha; Suliman Y Alomar; Dina M Khodeer
Journal:  Antibiotics (Basel)       Date:  2020-06-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.