Literature DB >> 19675031

What is the significance of tendon suture purchase?

J B Kim1, T de Wit, S E R Hovius, D A McGrouther, E T Walbeehm.   

Abstract

Repairs have been performed on porcine flexor tendons and subjected to tensile stress measurements to determine the effects and mechanism of core suture purchase (the length of the suture bite). Eighty-four pig trotter flexor profundus tendons were divided and repaired using four lengths of core suture purchase (1.33, 1, 0.66 and 0.33 cm) using a double modified Kessler repair (four strands, two knots) with a peripheral epitendinous suture. Tendon purchase was achieved by either bilateral equal purchase lengths or with one tendon purchase at a fixed depth of 1 cm. A separate group of tendons were incubated in blood for 24 hours to simulate the wound environment prior to testing. Tensile tests demonstrated a progressive increase of repair strength with purchase length. With the exception of the 0.33 cm group, video analysis demonstrated the mode of failure as suture failure and not due to suture pullout. Therefore, the increase in breaking strength cannot be attributed to a better grip of the tendon ends, but to the mechanical characteristics of the suture polymer. The tendency for the incubated tendons to fail more consistently by pullout rather than suture failure, particularly in the shorter purchase lengths, emphasises the importance of studying tendon purchase in vivo. The significance of ex vivo mechanical testing should be considered with caution.

Entities:  

Mesh:

Year:  2009        PMID: 19675031     DOI: 10.1177/1753193409104555

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  4 in total

1.  Improving Strength and Quality of Epitendinous Repairs.

Authors:  Angel Farinas; Michael Stephanides; Steven Schneeberger; Alonda Pollins; Nancy Cardwell; Wesley P Thayer
Journal:  Hand (N Y)       Date:  2018-12-05

Review 2.  Suture techniques for tendon repair; a comparative review.

Authors:  Shelley Rawson; Sarah Cartmell; Jason Wong
Journal:  Muscles Ligaments Tendons J       Date:  2013-08-11

3.  Suture-Only Repair Versus Suture Anchor-Augmented Repair for Achilles Tendon Ruptures With a Short Distal Stump: A Biomechanical Comparison.

Authors:  Michael A Boin; Matthew A Dorweiler; Christopher J McMellen; Gregory C Gould; Richard T Laughlin
Journal:  Orthop J Sports Med       Date:  2017-01-04

4.  Tendon Injuries of the Hand in Kirikkale, Turkey.

Authors:  Elif Sari
Journal:  World J Plast Surg       Date:  2016-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.