INTRODUCTION: Although not essential, molars hold their importance in terms of functional jaw stability, antagonist opposition, and support of facial height. Therefore, implant therapy is an attractive concept in molar areas. However, especially in the posterior mandible, the conventional two-stage surgical approach to implant therapy was reported to cause higher bone loss and/or higher implant failures with machined implants because of the peculiar anatomic and physiologic conditions of this area. As the TiUnite™ (Nobel Biocare AB, Göteborg, Sweden) surface results in faster bone healing than with machined-surface implants, it was hypothesized that this surface would also improve the performance of wide implants in posterior mandibles. Based on these assumptions, a protocol for immediately loaded implants for single molar replacement was developed.
PURPOSE: This paper aimed to report on the clinical and radiological performance of Brånemark System® TiUnite Wide Platform implants supporting single molars in the lower jaw, loaded immediately and followed for up to 5 years, and to assess if the benefit delivered by oxidized surfaces in the short run is also present after 5 years.
MATERIALS AND METHODS: The study includes 33 consecutive patients treated between March 2001 and September 2003 and monitored until September 2008 in two private dental offices. A total of 40 Brånemark System TiUnite Wide Platform MK III implants were placed. All implants were provided with provisional crowns in full centric occlusion at the time of surgery. Patients were clinically and radiologically followed up for up to 5 years.
RESULTS: Two implant failed so that the cumulative success rate at 5 years was 95.0%. The mean marginal bone remodeling (n = 38) expressed as mesial plus distal value averages was -1.17 mm (SD ± 0.90) at the 5-year time point.
CONCLUSION: Although limited by the number of patients treated in accordance with the protocol described, 5-year results encourage the use of immediately loaded single lower molars supported by Brånemark System Wide Platform TiUnite implants and further document the clinical advantages of titanium oxidized surfaces.
© 2009 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19673926     DOI: 10.1111/j.1708-8208.2009.00214.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  12 in total

1.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

2.  Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuick™ EB implant system.

Authors:  Jong-Hwa Kim; Young-Kyun Kim; Yang-Jin Yi; Pil-Young Yun; Hyo-Jung Lee; Myung-Jin Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2009-11-30       Impact factor: 1.904

3.  Meta-analysis of Failure and Survival Rate of Implant-supported Single Crowns, Fixed Partial Denture, and Implant Tooth-supported Prostheses.

Authors:  B C Muddugangadhar; G S Amarnath; Radhika Sonika; Pratik S Chheda; Ashu Garg
Journal:  J Int Oral Health       Date:  2015-09

4.  A Three-Dimensional Finite Element Study on the Biomechanical Simulation of Various Structured Dental Implants and Their Surrounding Bone Tissues.

Authors:  Gong Zhang; Hai Yuan; Xianshuai Chen; Weijun Wang; Jianyu Chen; Jimin Liang; Peng Zhang
Journal:  Int J Dent       Date:  2016-01-19

5.  Immediate Function of Anodically Oxidized Surface Implants (TiUnite™) for Fixed Prosthetic Rehabilitation: Retrospective Study with 10 Years of Follow-Up.

Authors:  Paulo Maló; Miguel de Araújo Nobre; Yolande Gonçalves; Armando Lopes; Ana Ferro
Journal:  Biomed Res Int       Date:  2016-12-29       Impact factor: 3.411

6.  Immediate functional loading of single implants: a multicenter study with 4 years of follow-up.

Authors:  Filiep Raes; Tammaro Eccellente; Carolina Lenzi; Michele Ortolani; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

7.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

8.  Effect of loading time on marginal bone loss around hydroxyapatite-coated implants.

Authors:  Young-Kyun Kim; Kyo-Jin Ahn; Pil-Young Yun; Minkyoung Kim; Hong-So Yang; Yang-Jin Yi; Ji-Hyun Bae
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-08-23

9.  Consecutive Case Series of Healed Single-Molar Sites Immediately Restored with Wide-Diameter Implants: A 1-Year Evaluation.

Authors:  Hadi Antoun; Pierre Cherfane; Bouchra Sojod
Journal:  Int J Dent       Date:  2016-04-18

10.  A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas.

Authors:  Sang-Yun Kim; Jeong-Kui Ku; Hyun-Suk Kim; Pil-Young Yun; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.