Literature DB >> 19673919

Clinical experience of TiUnite implants: a 5-year cross-sectional, retrospective follow-up study.

Bertil Friberg1, Torsten Jemt.   

Abstract

BACKGROUND: Little is known of the long-term clinical and radiographic performance of moderately rough surface implants.
PURPOSE: The aim of the present retrospective investigation was to study two pioneer cohorts of patients, that is, the first patients to receive Brånemark System implants with a moderately rough surface (TiUnite, Nobel Biocare AB, Göteborg, Sweden) at the present clinic. TiUnite implants were inserted either in compromised bone sites in a mixed-mouth concept together with turned implants or used solely. Patients were followed up over a period of 5 years with regard to implant survival and the marginal bone response.
MATERIALS AND METHODS: Patients who received both implant types (mixed group) comprised 41 subjects, and the second group (TiUnite group) comprised 70 subjects. A total of 110 turned and 68 TiUnite implants were placed in the mixed group, and 212 TiUnite implants in the TiUnite group. Follow-up radiographs were obtained at prosthesis placement and at the 1- and 5-year check-ups, and examined by independent observers.
RESULTS: One turned (0.9%) and two TiUnite (2.9%) implants failed in the mixed group, and three implants (1.6%) failed in the TiUnite group, indicating no significant differences between surfaces or groups (p < .05). The mean marginal bone loss at 5 years was 0.6 mm to 0.8 mm, also indicating no significant differences for the two implant types tested in the mixed group.
CONCLUSIONS: Cumulative survival rates for the two implant surfaces were favorable at 5 years, and the marginal bone loss was low and similar for both implant surfaces.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19673919     DOI: 10.1111/j.1708-8208.2009.00222.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  4 in total

1.  Stability of plasma electrolytic oxidation coating on titanium in artificial saliva.

Authors:  E Matykina; R Arrabal; M Mohedano; A Pardo; M C Merino; E Rivero
Journal:  J Mater Sci Mater Med       Date:  2012-10-17       Impact factor: 3.896

2.  Wettability and cellular response of UV light irradiated anodized titanium surface.

Authors:  Kyou-Hwa Park; Jai-Young Koak; Seong-Kyun Kim; Seong-Joo Heo
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

Review 3.  Prevalence of Peri-Implantitis in Implants with Turned and Rough Surfaces: a Systematic Review.

Authors:  Nikola Saulacic; Benoit Schaller
Journal:  J Oral Maxillofac Res       Date:  2019-03-31

4.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07
  4 in total