Literature DB >> 19673206

A practical way to improve contrast-to-noise ratio and quantitation for statistical-based iterative reconstruction in whole-body PET imaging.

Loïc Fin1, Pascal Bailly, Joël Daouk, Marc-Etienne Meyer.   

Abstract

In whole-body positron emission tomography (PET) imaging, the detection of small uptake foci (i.e., around two or three times the tomograph's spatial resolution) is a critical issue. Indeed, spatial resolution is altered by postreconstruction smoothing operations used to reduce the noise introduced by (among other things) an inaccurate system matrix. The authors previously proposed a device-dedicated projector, easily applicable on a clinical gantry, based on point-source measurements, which introduces less noise than a geometrical model. In the present study, they took advantage of the lower noise levels by reducing the postfilter and then quantified the approach's impact on image quality. This study was performed on an IEC Body Phantom Set filled with 18F (sphere-to-background activity ratio: 4:1). The same 3 min acquisition was reconstructed with either (i) a clinical system based on a geometrical tomographic operator (OSEM_CL) or (ii) an OSEM algorithm using the suggested system matrix (OSEM_DR). In order to compare the resulting images, they set the 3D Gaussian postfilter (3DGPF) for OSEM_DR so as to obtain similar background signal-to-noise ratio (SNR) to that of OSEM_CL with a Gaussian postfilter full width at half maximum of 5 mm (as recommended for whole-body imaging on a Biograph6). They then assessed the contrast-to-noise ratio (CNR) and quantitation [contrast recovery (CR)] for the phantom's four smallest spheres (with internal diameters of 10, 13, 17, and 22 mm). Evaluation of 3DGPFs ranging from 2.2 to 2.6 mm showed that a value of 2.4 mm in OSEM_DR gave the closest background SNR to that of OSEM_CL with a 3DGPF of 5 mm. For all studied targets, the CNR was higher with OSEM_DR than with OSEM_CL. For the 10 and 13 mm spheres, OSEM_DR increased the size of the CNR peaks by 37% and 20%, relative to OSEM_CL. The OSEM_DR technique yielded higher CR values than OSEM_CL did. For the 10, 13, 17, and 22 mm spheres, the CR values at eight iterations were 0.5, 0.6, 1.1, and 1.0 for OSEM_DR and 0.3, 0.4, 0.9, and 0.8 for OSEM_CL. They evaluated a practical method for determining a device-dedicated system matrix based on point-source acquisitions. This tomographic operator is more realistic than geometrical system matrix and introduces less noise into PET images during statistical reconstruction; it thus reduces the extent of postfiltering operations required. Thus, spatial resolution is better maintained with OSEM_DR than with clinical reconstruction. They showed that this method improves the contrast-to-noise ratio and quantification of uptake foci (especially those that are at the system's limit of detection) and, in a clinical context, could allow better detection and earlier diagnosis.

Entities:  

Mesh:

Year:  2009        PMID: 19673206     DOI: 10.1118/1.3152116

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM.

Authors:  D Wiant; J A Gersh; M Bennett; J D Bourland
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

Review 2.  Influences on PET Quantification and Interpretation.

Authors:  Julian M M Rogasch; Frank Hofheinz; Lutz van Heek; Conrad-Amadeus Voltin; Ronald Boellaard; Carsten Kobe
Journal:  Diagnostics (Basel)       Date:  2022-02-10

3.  Influence of reconstruction settings on the performance of adaptive thresholding algorithms for FDG-PET image segmentation in radiotherapy planning.

Authors:  Roberta Matheoud; Patrizia Della Monica; Gianfranco Loi; Luca Vigna; Marco Krengli; Eugenio Inglese; Marco Brambilla
Journal:  J Appl Clin Med Phys       Date:  2011-01-30       Impact factor: 2.102

4.  PET imaging of occult tumours by temporal integration of tumour-acidosis signals from pH-sensitive 64Cu-labelled polymers.

Authors:  Gang Huang; Tian Zhao; Chensu Wang; Kien Nham; Yahong Xiong; Xiaofei Gao; Yihui Wang; Guiyang Hao; Woo-Ping Ge; Xiankai Sun; Baran D Sumer; Jinming Gao
Journal:  Nat Biomed Eng       Date:  2019-06-24       Impact factor: 25.671

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.