BACKGROUND: Atherosclerotic renal artery (RA) stenosis contributes to hypertension, renal insufficiency and end stage renal disease, and is independently associated with adverse cardiovascular events. Percutaneous renal intervention is efficacious in treating renovascular hypertension and may be effective in stabilizing or improving renal function, thereby reducing cardiovascular risk. However, high rates of procedural complications have been reported. OBJECTIVES: To determine the nature and frequency of complications of percutaneous renal intervention using contemporary techniques and equipment in a high-volume cardiac catheterization laboratory. METHODS: Consecutive patients undergoing attempted RA stenting for atherosclerotic RA stenosis in the cardiac catheterization laboratory at the Vancouver General Hospital (Vancouver, British Columbia) between June 2000 and March 2007 were enrolled in a prospective registry. Baseline clinical characteristics, procedural and technical information, and complications were recorded. RESULTS: A total of 132 RAs were stented in 106 patients during 108 procedures. The procedural success rate was 100%, with no related death, myocardial infarction, nephrectomy or dialysis. Major complications included three pseudoaneurysms (2.8%) and acute deterioration in renal function in six patients (5.5%), although renal function returned to baseline in one patient at 12 months. CONCLUSIONS: RA stenting can be successfully and safely performed using contemporary techniques, and the low complication rates described should be the minimum standard for contemporary trials evaluating RA stenting.
BACKGROUND:Atherosclerotic renal artery (RA) stenosis contributes to hypertension, renal insufficiency and end stage renal disease, and is independently associated with adverse cardiovascular events. Percutaneous renal intervention is efficacious in treating renovascular hypertension and may be effective in stabilizing or improving renal function, thereby reducing cardiovascular risk. However, high rates of procedural complications have been reported. OBJECTIVES: To determine the nature and frequency of complications of percutaneous renal intervention using contemporary techniques and equipment in a high-volume cardiac catheterization laboratory. METHODS: Consecutive patients undergoing attempted RA stenting for atherosclerotic RA stenosis in the cardiac catheterization laboratory at the Vancouver General Hospital (Vancouver, British Columbia) between June 2000 and March 2007 were enrolled in a prospective registry. Baseline clinical characteristics, procedural and technical information, and complications were recorded. RESULTS: A total of 132 RAs were stented in 106 patients during 108 procedures. The procedural success rate was 100%, with no related death, myocardial infarction, nephrectomy or dialysis. Major complications included three pseudoaneurysms (2.8%) and acute deterioration in renal function in six patients (5.5%), although renal function returned to baseline in one patient at 12 months. CONCLUSIONS: RA stenting can be successfully and safely performed using contemporary techniques, and the low complication rates described should be the minimum standard for contemporary trials evaluating RA stenting.
Authors: John H Rundback; David Sacks; K Craig Kent; Christopher Cooper; Daniel Jones; Timothy Murphy; Kenneth Rosenfield; Christopher White; Michael Bettmann; Stanley Cortell; Jules Puschett; Daniel G Clair; Patricia Cole Journal: J Vasc Interv Radiol Date: 2002-10 Impact factor: 3.464
Authors: Felipe Ramos; Carol Kotliar; Daniel Alvarez; Hugo Baglivo; Pablo Rafaelle; Hugo Londero; Ramiro Sánchez; Christopher S Wilcox Journal: Kidney Int Date: 2003-01 Impact factor: 10.612
Authors: J Bakker; P P Goffette; M Henry; W P Mali; J P Melki; J G Moss; C Rabbia; E Therasse; K R Thomson; S Thurnher; C Vignali Journal: Cardiovasc Intervent Radiol Date: 1999 Nov-Dec Impact factor: 2.740
Authors: Vladimir Ivanovic; Michael A McKusick; C Michael Johnson; Enrique A Sabater; James C Andrews; Jerome F Breen; Haraldur Bjarnason; Sanjay Misra; Anthony W Stanson Journal: J Vasc Interv Radiol Date: 2003-02 Impact factor: 3.464
Authors: David J Kennedy; William R Colyer; Pamela S Brewster; Mary Ankenbrandt; Mark W Burket; Attila S Nemeth; Sadik A Khuder; William J Thomas; Joseph I Shapiro; Christopher J Cooper Journal: Am J Kidney Dis Date: 2003-11 Impact factor: 8.860