Monte Carlo simulation of various source-product geometries for a proposed multi-product gamma irradiator facility.

K Biju1, T Palani Selvam, D S Lavale.   

Abstract

Radiation processing plants are designed to deliver a prescribed dose to product materials within the acceptable uniformity to meet the national standards. The dose uniformity ratios for four different product geometries of a proposed 37 PBq (10(6) Ci) 60Co-based, multi-product irradiator facility in India are evaluated using the Monte Carlo method for various product densities, 0.15 g cm-3, 0.4 g cm-3, and 0.6 g cm-3. The calculations are also carried out using the point kernel method for comparison purposes. The agreement between Monte Carlo and point kernel methods is within 3 to 15%. The suitable product geometry is identified based on dose uniformity ratios.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19667801     DOI: 10.1097/HP.0b013e3181ac4cd7

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  1 in total

1.  Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers.

Authors:  Biju Keshavkumar
Journal:  J Med Phys       Date:  2012-07