Radiation processing plants are designed to deliver a prescribed dose to product materials within the acceptable uniformity to meet the national standards. The dose uniformity ratios for four different product geometries of a proposed 37 PBq (10(6) Ci) 60Co-based, multi-product irradiator facility in India are evaluated using the Monte Carlo method for various product densities, 0.15 g cm-3, 0.4 g cm-3, and 0.6 g cm-3. The calculations are also carried out using the point kernel method for comparison purposes. The agreement between Monte Carlo and point kernel methods is within 3 to 15%. The suitable product geometry is identified based on dose uniformity ratios.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19667801 DOI: 10.1097/HP.0b013e3181ac4cd7