OBJECTIVE: The objective of this study was to assess predictors of residual shunts after percutaneous patent foramen ovale (PFO) closure with Amplatzer PFO occluder (AGA Medical Corporation, Golden Valley, MN, USA).
METHODS: All percutaneous PFO closures, using Amplatzer PFO occluder performed at a tertiary center between May 2002 and August 2006, were reviewed. Follow-up, including saline contrast transesophageal echocardiography, was performed in all patients 6 months after the intervention. PATIENTS: A total of 135 procedures were performed. Mean age of the patients was 51 years. The indication for PFO closure was an ischemic cerebrovascular event in 92%, paradoxical systemic embolism in 4%, and a diving accident in 4%. Recurrent events prior to PFO closure were noted in 34%. A concomitant atrial septal aneurysm was present in 61%.
RESULTS: At 6 months follow-up, a residual shunt was detected in 26 patients (19%). Residual shunts were more common in patients with an atrial septal aneurysm (27 vs. 8%, P= .01) and in patients treated with a 35-mm compared with a 25-mm device (39 vs. 15%, P= .01). A concomitant atrial septal aneurysm remained independently associated with residual shunts when controlled for body mass index, gender, age, atrial dimensions, and presence of a Chiari network (odds ratio 4.1, 95% confidence intervals 1.1-15.0).
CONCLUSION: The presence of atrial septal aneurysms in patients undergoing percutaneous PFO closure with an Amplatzer PFO occluder significantly increases the rate of residual shunts at 6 months follow-up, even if 35-mm devices are used.

Entities:  

Mesh:

Year:  2009        PMID: 19664027     DOI: 10.1111/j.1747-0803.2009.00302.x

Source DB:  PubMed          Journal:  Congenit Heart Dis        ISSN: 1747-079X            Impact factor:   2.007


  4 in total

1.  Long-term results of the amplatzer cribriform occluder for patent foramen ovale with associated atrial septal aneurysm: impact on occlusion rate and left atrial functional remodelling.

Authors:  Gianluca Rigatelli; Fabio Dell'avvocata; Paolo Cardaioli; Gabriele Braggion; Massimo Giordan; Alberto Mazza; Chiara Fraccaro; Mauro Chinaglia; Jack P Chen
Journal:  Am J Cardiovasc Dis       Date:  2011-12-15

2.  Recurrent stroke secondary to late patent foramen ovale-closure device thrombus: a case report.

Authors:  Lennox Jerzyna; Abhisheik Prashar; George Youssef; Mark Sader
Journal:  Eur Heart J Case Rep       Date:  2021-08-04

3.  Efficacy and safety of transcatheter closure in adults with large or small atrial septal defects.

Authors:  Matthias R Meyer; David J Kurz; Alain M Bernheim; Oliver Kretschmar; Franz R Eberli
Journal:  Springerplus       Date:  2016-10-21

4.  Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale.

Authors:  Yajuan Du; Hang Xie; Hui Shao; Gesheng Cheng; Lu He; Xingye Wang; Xumei He; Beidi Lan; Yushun Zhang; Gang Tian
Journal:  Cardiovasc Ther       Date:  2022-07-22       Impact factor: 3.368

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.