Literature DB >> 19661571

Ring artifact correction for high-resolution micro CT.

Yiannis Kyriakou1, Daniel Prell, Willi A Kalender.   

Abstract

In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis.

Entities:  

Mesh:

Year:  2009        PMID: 19661571     DOI: 10.1088/0031-9155/54/17/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Visible-Light Initiated Free-Radical/Cationic Ring-Opening Hybrid Photopolymerization of Methacrylate/Epoxy: Polymerization Kinetics, Crosslinking Structure, and Dynamic Mechanical Properties.

Authors:  Xueping Ge; Qiang Ye; Linyong Song; Anil Misra; Paulette Spencer
Journal:  Macromol Chem Phys       Date:  2015-02-11       Impact factor: 2.527

2.  Use of a CMOS-based micro-CT system to validate a ring artifact correction algorithm on low-dose image data.

Authors:  Alexander R Podgorsak; S V Setlur Nagesh; Daniel Bednarek; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

Review 3.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging.

Authors:  Eman Namati; Jacqueline Thiesse; Jessica C Sieren; Alan Ross; Eric A Hoffman; Geoffrey McLennan
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

5.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

6.  Comparison of ring artifact removal methods using flat panel detector based CT images.

Authors:  Emran M Abu Anas; Jae G Kim; Soo Y Lee; K Hasan
Journal:  Biomed Eng Online       Date:  2011-08-17       Impact factor: 2.819

7.  Ultra High-Resolution In vivo Computed Tomography Imaging of Mouse Cerebrovasculature Using a Long Circulating Blood Pool Contrast Agent.

Authors:  Zbigniew Starosolski; Carlos A Villamizar; David Rendon; Michael J Paldino; Dianna M Milewicz; Ketan B Ghaghada; Ananth V Annapragada
Journal:  Sci Rep       Date:  2015-05-18       Impact factor: 4.379

8.  A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector.

Authors:  Mohamed Elsayed Eldib; Mohamed Hegazy; Yang Ji Mun; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Sensors (Basel)       Date:  2017-01-30       Impact factor: 3.576

9.  Study of Image Qualities From 6D Robot-Based CBCT Imaging System of Small Animal Irradiator.

Authors:  Sunil Sharma; Ganesh Narayanasamy; Richard Clarkson; Ming Chao; Eduardo G Moros; Xin Zhang; Yulong Yan; Marjan Boerma; Nava Paudel; Steven Morrill; Peter Corry; Robert J Griffin
Journal:  Technol Cancer Res Treat       Date:  2017-03-30

10.  Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Danieli Moura Brasil; Daniela Verardi Madlum; Francisco Haiter-Neto; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-06-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.