Review of portable CT with assessment of a dedicated head CT scanner.

Z Rumboldt1, W Huda, J W All.   

Abstract

This article reviews a number of portable CT scanners for clinical imaging. These include the CereTom, Tomoscan, xCAT ENT, and OTOscan. The Tomoscan scanner consists of a gantry with multisection detectors and a detachable table. It can perform a full-body scanning, or the gantry can be used without the table to scan the head. The xCAT ENT is a conebeam CT scanner that is intended for intraoperative scanning of cranial bones and sinuses. The OTOscan is a multisection CT scanner intended for imaging in ear, nose, and throat settings and can be used to assess bone and soft tissue of the head. We also specifically evaluated the technical and clinical performance of the CereTom, a scanner designed specifically for neuroradiologic head imaging. The contrast performance of this scanner permitted the detection of 4-mm low-contrast lesions, and the limiting spatial resolution was 7 line pairs per centimeter. The measured volume of the CT dose index (CTDI(vol)) for a standard head CT scan was 41 mGy (120 kV/14 mAs). All clinical images were of diagnostic quality, and the average patient effective dose was 1.7 mSv. We conclude that the CereTom portable CT scanner generates satisfactory clinical images at acceptable patient doses.

Entities:  

Mesh:

Year:  2009        PMID: 19661166     DOI: 10.3174/ajnr.A1603

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  32 in total

1.  Head computed tomography scanning during pediatric neurocritical care: diagnostic yield and the utility of portable studies.

Authors:  Kerri L LaRovere; Molly S Brett; Robert C Tasker; Keith J Strauss; Jeffrey P Burns
Journal:  Neurocrit Care       Date:  2012-04       Impact factor: 3.210

2.  Cerebral computed tomography perfusion at the bedside using a portable CT scanner: report of two cases.

Authors:  Grace M Lee; Claudia J Chaves
Journal:  J Neurol       Date:  2010-06-27       Impact factor: 4.849

3.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

4.  Limited Evaluation of Image Quality Produced by a Portable Head CT Scanner (CereTom) in a Neurosurgery Centre.

Authors:  Ariz Chong Abdullah; Johari Siregar Adnan; Noor Azman A Rahman; Ravikant Palur
Journal:  Malays J Med Sci       Date:  2017-02-24

5.  A comparison of linear interpolation models for iterative CT reconstruction.

Authors:  Katharina Hahn; Harald Schöndube; Karl Stierstorfer; Joachim Hornegger; Frédéric Noo
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

6.  Metal and motion artifacts by cone beam computed tomography (CBCT) in dental and maxillofacial study.

Authors:  Cosimo Nardi; Claudia Borri; Francesco Regini; Linda Calistri; Alessandro Castellani; Chiara Lorini; Stefano Colagrande
Journal:  Radiol Med       Date:  2015-01-30       Impact factor: 3.469

7.  Value of routine immediate postoperative brain computerized tomography in pediatric neurosurgical patients.

Authors:  Jong-myung Jung; Ji Yeoun Lee; Ji Hoon Phi; Seung-Ki Kim; Jung-Eun Cheon; In-One Kim; Kyu-Chang Wang
Journal:  Childs Nerv Syst       Date:  2012-02-28       Impact factor: 1.475

8.  Comparison of Intraoperative Portable CT Scanners in Skull Base and Endoscopic Sinus Surgery: Single Center Case Series.

Authors:  David B Conley; Bruce Tan; Bernard R Bendok; H Hunt Batjer; Rakesh Chandra; Douglas Sidle; Rudy J Rahme; Joseph G Adel; Andrew J Fishman
Journal:  Skull Base       Date:  2011-07

9.  Xenon-enhanced cerebral blood flow at 28% xenon provides uniquely safe access to quantitative, clinically useful cerebral blood flow information: a multicenter study.

Authors:  A P Carlson; A M Brown; E Zager; K Uchino; M P Marks; C Robertson; G P Sinson; A Marmarou; H Yonas
Journal:  AJNR Am J Neuroradiol       Date:  2011-06-23       Impact factor: 3.825

Review 10.  Neuromonitoring in the neonatal ECMO patient.

Authors:  Nan Lin; John Flibotte; Daniel J Licht
Journal:  Semin Perinatol       Date:  2018-02-02       Impact factor: 3.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.