Literature DB >> 19657658

Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits.

Long-Jiang Zhang1, Xue Chai, Sheng-Yong Wu, Yan-E Zhao, Xiao-Bo Hu, Yu-Xiao Hu, Yang-Bo Xue, Gui-Fen Yang, Hong Zhu, Guang-Ming Lu.   

Abstract

The purpose of the study was to compare the ability of dual energy CT (DECT) and perfusion scintigraphy (PS) to detect pulmonary embolism (PE) in a rabbit model. Gelfoam (n = 20) or saline (n = 4) was injected into the femoral vein of rabbits. After 2 h, DECT pulmonary angiography (CTPA) was used to create blood flow imaging (BFI) and fusion images. The rabbits then underwent PS. Pathological determination of locations and numbers of lung lobes with PE was recorded. The sensitivity and specificity for BFI, CTPA, fused images and PS were calculated using the pathological results as reference standards. Compared with pathological evaluation, CTPA correctly identified PE in 40 lobes and absence of emboli in 80 lobes, corresponding to a sensitivity and specificity of 100%. BFI and fused images correctly identified PE in 40 lobes and the absence of emboli in 78 lobes, corresponding to a sensitivity and specificity of 100% and 98%, respectively. PS correctly detected 27 lobes with PE and 65 lobes without PE, corresponding to a sensitivity and specificity of 68% and 81%, respectively. BFI, CTPA and fused images derived from a single contrast-enhanced DECT provide a higher diagnostic accuracy of detecting PE than PS in a rabbit model.

Entities:  

Mesh:

Year:  2009        PMID: 19657658     DOI: 10.1007/s00330-009-1518-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  29 in total

1.  Sensitivity and specificity of perfusion scintigraphy combined with chest radiography for acute pulmonary embolism in PIOPED II.

Authors:  H Dirk Sostman; Massimo Miniati; Alexander Gottschalk; Fadi Matta; Paul D Stein; Massimo Pistolesi
Journal:  J Nucl Med       Date:  2008-10-16       Impact factor: 10.057

2.  Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms--initial observations.

Authors:  Hersh Chandarana; Myrna C B Godoy; Ioannis Vlahos; Anno Graser; James Babb; Christianne Leidecker; Michael Macari
Journal:  Radiology       Date:  2008-09-23       Impact factor: 11.105

3.  Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom.

Authors:  Daniel T Boll; Elmar M Merkle; Erik K Paulson; Thorsten R Fleiter
Journal:  Radiology       Date:  2008-04-18       Impact factor: 11.105

Review 4.  Review of criteria appropriate for a very low probability of pulmonary embolism on ventilation-perfusion lung scans: a position paper.

Authors:  P D Stein; A Gottschalk
Journal:  Radiographics       Date:  2000 Jan-Feb       Impact factor: 5.333

Review 5.  Approaches to CT perfusion imaging in pulmonary embolism.

Authors:  Joachim E Wildberger; U Joseph Schoepf; Andreas H Mahnken; Peter Herzog; Hendrik Ditt; Matthias U Niethammer; Stefan Schaller; Ernst Klotz; Rolf W Günther
Journal:  Semin Roentgenol       Date:  2005-01       Impact factor: 0.800

6.  Diagnosis of pulmonary embolism: comparison of CT angiography and MR angiography in canines.

Authors:  D R Hurst; E A Kazerooni; D Stafford-Johnson; D M Williams; J F Platt; P N Cascade; M R Prince
Journal:  J Vasc Interv Radiol       Date:  1999-03       Impact factor: 3.464

7.  Prospective evaluation of unsuspected pulmonary embolism on contrast enhanced multidetector CT (MDCT) scanning.

Authors:  Gillian Ritchie; Simon McGurk; Catriona McCreath; Catriona Graham; John T Murchison
Journal:  Thorax       Date:  2006-12-08       Impact factor: 9.139

8.  Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion.

Authors:  Romain Grosjean; Benoît Sauer; Rui Matias Guerra; Michel Daudon; Alain Blum; Jacques Felblinger; Jacques Hubert
Journal:  AJR Am J Roentgenol       Date:  2008-03       Impact factor: 3.959

9.  Acute pulmonary embolism: sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study.

Authors:  H Dirk Sostman; Paul D Stein; Alexander Gottschalk; Fadi Matta; Russell Hull; Larry Goodman
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

10.  Dual energy CT for the assessment of lung perfusion--correlation to scintigraphy.

Authors:  Sven F Thieme; Christoph R Becker; Marcus Hacker; Konstantin Nikolaou; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Eur J Radiol       Date:  2008-09-05       Impact factor: 3.528

View more
  21 in total

1.  Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study.

Authors:  Long-Jiang Zhang; Jin Peng; Sheng-Yong Wu; Z Jane Wang; Xin-Sheng Wu; Chang-Sheng Zhou; Xue-Man Ji; Guang-Ming Lu
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

Review 2.  Dual-energy computed tomography in pulmonary embolism.

Authors:  G-M Lu; S-Y Wu; B M Yeh; L-J Zhang
Journal:  Br J Radiol       Date:  2010-06-15       Impact factor: 3.039

3.  Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT.

Authors:  Ralf W Bauer; Sebastian Kramer; Matthias Renker; Boris Schell; Maya Christina Larson; Martin Beeres; Thomas Lehnert; Volkmar Jacobi; Thomas J Vogl; Josef Matthias Kerl
Journal:  Eur Radiol       Date:  2011-05-27       Impact factor: 5.315

Review 4.  State of the art: utility of multi-energy CT in the evaluation of pulmonary vasculature.

Authors:  Prabhakar Rajiah; Yuki Tanabe; Sasan Partovi; Alastair Moore
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-02       Impact factor: 2.357

Review 5.  Dual-energy lung perfusion and ventilation CT in children.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2013-02-16

Review 6.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

7.  Lung ischaemia-reperfusion injury in a canine model: dual-energy CT findings with pathophysiological correlation.

Authors:  L Lu; K Xu; L J Zhang; J Morelli; A W Krazinski; J R Silverman; U J Schoepf; G M Lu
Journal:  Br J Radiol       Date:  2014-02-07       Impact factor: 3.039

8.  Severity assessment of pulmonary embolism using dual energy CT - correlation of a pulmonary perfusion defect score with clinical and morphological parameters of blood oxygenation and right ventricular failure.

Authors:  Sven F Thieme; Nima Ashoori; Fabian Bamberg; Wieland H Sommer; Thorsten R C Johnson; Hanno Leuchte; Alexander Becker; Daniel Maxien; Andreas D Helck; Jürgen Behr; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Eur Radiol       Date:  2011-09-14       Impact factor: 5.315

9.  Feasibility of gadolinium-enhanced dual energy CT pulmonary angiography: a pilot study in rabbits.

Authors:  Long Jiang Zhang; Zhen Jane Wang; Li Lu; Bo Chen; Guang Ming Lu
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-26       Impact factor: 2.357

10.  Acute and subacute dual energy CT findings of pulmonary embolism in rabbits: correlation with histopathology.

Authors:  X Chai; L-J Zhang; B M Yeh; Y-E Zhao; X-B Hu; G-M Lu
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.