Literature DB >> 19651545

Immunogold-silver staining-on-a-chip biosensor based on cross-flow chromatography.

Il-Hoon Cho1, Sung-Min Seo, Eui-Hwan Paek, Se-Hwan Paek.   

Abstract

Immunogold-silver staining (IGSS) was adopted in cross-flow chromatographic analysis in which immunological reactions and silver intensification were sequentially conducted in the vertical and horizontal directions, respectively. Factors controlling the performance, except the silver substrate solution, were optimized to increase the signal-to-background ratio in measurements of cardiac troponin I as a model analyte. In generating the signal, the size of colloidal gold catalyst was critical; the smallest size (5-nm diameter) in the selected range yielded the highest colorimetric signal. To maintain the low background, two processes, blocking the remaining surfaces of membrane after antibody immobilization and washing the residual tracer after immunological reaction, were necessary. Self-nucleation of silver ions also caused a background signal and was controlled to some degree by decreasing the hydrodynamic force that arose when the substrate solution was supplied in the horizontal direction. Finally, a new chip (IGSS-on-a-chip; IOC) that allowed for convenient, efficient IGSS was produced by injection molding of plastic. This method enhanced the detection capability by 51-fold compared to the conventional rapid test kit using 30nm-sized colloidal gold as the tracer. The IOC biosensor results also showed that silver intensification yield via cross flow after immunological reaction was 19% higher than that by traditional incubation. 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19651545     DOI: 10.1016/j.jchromb.2009.07.016

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  13 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

2.  Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format.

Authors:  Elain Fu; Tinny Liang; Jared Houghtaling; Sujatha Ramachandran; Stephen A Ramsey; Barry Lutz; Paul Yager
Journal:  Anal Chem       Date:  2011-09-21       Impact factor: 6.986

3.  Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection.

Authors:  Elain Fu; Tinny Liang; Paolo Spicar-Mihalic; Jared Houghtaling; Sujatha Ramachandran; Paul Yager
Journal:  Anal Chem       Date:  2012-04-26       Impact factor: 6.986

4.  Programmed sample delivery on a pressurized paper.

Authors:  Joong Ho Shin; Juhwan Park; Seung Hoon Kim; Je-Kyun Park
Journal:  Biomicrofluidics       Date:  2014-10-24       Impact factor: 2.800

Review 5.  Current Trends in Ligand Binding Real-Time Measurement Technologies.

Authors:  Stephanie Fraser; Judy Y Shih; Mark Ware; Edward O'Connor; Mark J Cameron; Martin Schwickart; Xuemei Zhao; Karin Regnstrom
Journal:  AAPS J       Date:  2017-03-20       Impact factor: 4.009

Review 6.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

7.  Controlled release of dry reagents in porous media for tunable temporal and spatial distribution upon rehydration.

Authors:  Gina E Fridley; Huy Q Le; Elain Fu; Paul Yager
Journal:  Lab Chip       Date:  2012-11-07       Impact factor: 6.799

8.  Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics.

Authors:  Barry Lutz; Tinny Liang; Elain Fu; Sujatha Ramachandran; Peter Kauffman; Paul Yager
Journal:  Lab Chip       Date:  2013-07-21       Impact factor: 6.799

9.  Long-term dry storage of an enzyme-based reagent system for ELISA in point-of-care devices.

Authors:  Sujatha Ramachandran; Elain Fu; Barry Lutz; Paul Yager
Journal:  Analyst       Date:  2014-03-21       Impact factor: 4.616

Review 10.  Challenges of the Nano-Bio Interface in Lateral Flow and Dipstick Immunoassays.

Authors:  Helena de Puig; Irene Bosch; Lee Gehrke; Kimberly Hamad-Schifferli
Journal:  Trends Biotechnol       Date:  2017-09-28       Impact factor: 19.536

View more