New high-performance liquid chromatography method for the determination of (R)-warfarin and (S)-warfarin using chiral separation on a glycopeptide-based stationary phase.

Jana Malakova1, Petr Pavek, Lucie Svecova, Iveta Jokesova, Pavel Zivny, Vladimir Palicka.   

Abstract

Warfarin is a well-known anticoagulant agent that occurs in two enantiomers, (R)-(+)-warfarin and (S)-(-)-warfarin. A new liquid chromatography method for the determination of both enantiomers was developed, validated and applied in in vitro studies with the aim of evaluating the accumulation of (R)-warfarin and (S)-warfarin in the hepatoma HepG2 cell line. OptiMEM cell cultivation medium samples and cellular lysates were purified using Waters Oasis MAX extraction cartridges. The chiral separation of warfarin and the internal standard p-chlorowarfarin enantiomers was performed on an Astec Chirobiotic V2 column at a flow rate of 1.2mL/min. The mobile phase was composed of 31% acetonitrile, 5% of methanol and 64% of ammonium acetate buffer (10mmol/L, pH 4.1). The enantiomers were quantified using a fluorescence detector (lambda(excit)=320nm, lambda(emiss)=415nm). The limit of detection was found to be 0.121micromol/L of (S)-warfarin and 0.109micromol/L of (R)-warfarin. The range of applicability and linearity was estimated from 0.25 to 100micromol/L. The precision ranged from 1.3% to 12.2% of the relative standard deviation, and the accuracy reached acceptable values from 95.5% to 108.4%. The new bioanalytical method confirmed the same accumulation of (R)-warfarin and (S)-warfarin in the hepatoma HepG2 cell line.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19643683     DOI: 10.1016/j.jchromb.2009.07.009

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  2 in total

1.  Validation and Application of a Simple UHPLC-MS-MS Method for the Enantiospecific Determination of Warfarin in Human Urine.

Authors:  Osama Y Alshogran; Andrew J Ocque; François A Leblond; Vincent Pichette; Thomas D Nolin
Journal:  J Chromatogr Sci       Date:  2015-12-11       Impact factor: 1.618

2.  Validation of warfarin enantiomer analysis method in plasma using high-performance liquid chromatography fluorescence detector.

Authors:  Norisca Aliza Putriana; Taofik Rusdiana; Tina Rostinawati; Mohammad Rizki Akbar; Febrina Amelia Saputri; Siti Utami
Journal:  J Adv Pharm Technol Res       Date:  2022-01-21