Literature DB >> 19643292

Comparison of loop-tendon versus end-weave methods for tendon transfer or grafting in rabbits.

Suk Ha Jeon1, Moon Sang Chung, Goo Hyun Baek, Young Ho Lee, Sae Hoon Kim, Hyun Sik Gong.   

Abstract

PURPOSE: The loop-tendon method for the stabilization of tendon transfers or grafts has been demonstrated previously to have greater initial tensile strength than that of the end-weave method. To our knowledge, a comparison of the mechanical strengths of these methods over the early postoperative period has not been made. The purpose of this study was to compare the mechanical strengths of loop-tendon and end-weave methods of repair during the early postoperative period in rabbit hind limb tendons.
METHODS: In bilateral hind limbs of 30 New Zealand white rabbits of an average weight of 3.5 kg, a distally cut gastrocnemius Achilles' tendon and a proximally cut flexor digitorum superficialis tendon were connected to each other by using the loop-tendon method with 5 stitches in one limb and a 1-pass end-weave method in the contralateral limb. Postoperatively, all rabbits were immobilized by a short-leg cylinder cast. Six rabbits were killed at each of the following time points: immediately after surgery (baseline) and at 1, 2, 3, and 4 weeks postoperatively. Repaired tendons were harvested and were loaded to failure in a tensile load-testing machine to record the ultimate strength and to calculate the absorbed energy.
RESULTS: Ultimate tensile loads were significantly higher in the loop-tendon method group than in the end-weave group from baseline to 3 weeks postoperatively, but there was no difference at 4 weeks postoperatively. During the postoperative period, the ultimate tensile load and absorbed energy decreased over the first 2 weeks postoperatively and then increased to reach baseline strengths at 3 weeks postoperatively in both groups.
CONCLUSIONS: The loop-tendon method provided greater strength than that of the end-weave method during the early postoperative period in rabbit tendons. The loop-tendon method may provide greater surgical repair strength during the early postoperative rehabilitation period than the end-weave method.

Entities:  

Mesh:

Year:  2009        PMID: 19643292     DOI: 10.1016/j.jhsa.2009.02.025

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  1 in total

1.  Comparison of step-cut and Pulvertaft attachment for flexor tendon graft: a biomechanics evaluation in an in vitro canine model.

Authors:  T Hashimoto; A R Thoreson; K-N An; P C Amadio; C Zhao
Journal:  J Hand Surg Eur Vol       Date:  2012-04-04