Literature DB >> 19641064

Discarding the initial aliquot of blood does not reduce contamination rates in intravenous-catheter-drawn blood cultures.

Sukrut Dwivedi1, Rohit Bhalla, Donald R Hoover, Melvin P Weinstein.   

Abstract

Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.

Entities:  

Mesh:

Year:  2009        PMID: 19641064      PMCID: PMC2738108          DOI: 10.1128/JCM.00292-09

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  16 in total

1.  Contamination of catheter-drawn blood cultures.

Authors:  R J Everts; E N Vinson; P O Adholla; L B Reller
Journal:  J Clin Microbiol       Date:  2001-09       Impact factor: 5.948

2.  The antimicrobial action of heparin.

Authors:  J F CHRISTMAN; D G DOHERTY
Journal:  J Bacteriol       Date:  1956-10       Impact factor: 3.490

3.  The effect of heparin on the growth of bacteria and yeasts.

Authors:  J R WARREN; F GRAHAM
Journal:  J Bacteriol       Date:  1950-08       Impact factor: 3.490

4.  Comparison of push-pull versus discard method from central venous catheters for blood testing.

Authors:  K R Holmes
Journal:  J Intraven Nurs       Date:  1998 Sep-Oct

5.  The reliability of blood sampling from peripheral intravenous infusion lines. Complete blood cell counts, electrolyte panels, and survey panels.

Authors:  M Mohler; Y Sato; K Bobick; L C Wise
Journal:  J Intraven Nurs       Date:  1998 Jul-Aug

6.  Reliability of blood cultures collected from intravascular catheter versus venipuncture.

Authors:  J K Bryant; C L Strand
Journal:  Am J Clin Pathol       Date:  1987-07       Impact factor: 2.493

7.  Methods of drawing blood samples through central venous catheters in pediatric patients undergoing bone marrow transplant: results of a national survey.

Authors:  C A Keller
Journal:  Oncol Nurs Forum       Date:  1994-06       Impact factor: 2.172

8.  Contamination rates of blood cultures obtained by dedicated phlebotomy vs intravenous catheter.

Authors:  Alonna Norberg; Norman C Christopher; Maria L Ramundo; John R Bower; Shirley A Berman
Journal:  JAMA       Date:  2003-02-12       Impact factor: 56.272

Review 9.  Developing a protocol for obtaining blood cultures from central venous catheters and peripheral sites.

Authors:  Linda M Penwarden; Paul G Montgomery
Journal:  Clin J Oncol Nurs       Date:  2002 Sep-Oct       Impact factor: 1.027

10.  Comparing two methods to obtain blood specimens from pediatric central venous catheters.

Authors:  Sharon Jackson Barton; Teresa Chase; Barbara Latham; Mary Kay Rayens
Journal:  J Pediatr Oncol Nurs       Date:  2004 Nov-Dec       Impact factor: 1.636

View more
  2 in total

1.  Biographical feature: Melvin P. Weinstein, M.D.

Authors:  Betty A Forbes
Journal:  J Clin Microbiol       Date:  2013-06-05       Impact factor: 5.948

2.  Blood Culture Contaminants in a Paediatric Population Retrospective study from a tertiary hospital in Oman.

Authors:  Mohamed A El-Naggari; Sharef W Al-Mulaabed; Zakaria Al-Muharrmi; Renjith Mani; Rana Abdelrahim; Reem Abdwani
Journal:  Sultan Qaboos Univ Med J       Date:  2017-06-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.