Literature DB >> 19640738

Removal of the G2 filter: differences between implantation times greater and less than 180 days.

Frank C Lynch1, Stephanie Kekulawela.   

Abstract

PURPOSE: To investigate whether filters implanted for longer periods are more difficult or hazardous to remove.
MATERIALS AND METHODS: A retrospective review of G2 inferior vena cava filter removals was performed. Objective measures reflecting the difficulty of the removal procedure were evaluated for differences required to remove a filter with an implantation period greater or less than 180 days.
RESULTS: One hundred seventy of 174 G2 filters were successfully removed (97.7% success rate). There was no significant difference in the success rate (P = .86), total procedure time (P = .87), fluoroscopy time (P = .13), or contrast medium use (P = .22) required to remove filters implanted for more than 180 days compared to those implanted for a shorter period of time. There was no significant difference in the frequency of filter movement (P = .90), tilt (P = .87), and caval penetration (P = .41) between the two groups. Six filter fractures were observed, all with implantation times greater than 180 days.
CONCLUSIONS: The removal of a G2 filter that has been in place for more than 180 days can be performed as easily, as safely, and with a similar degree of success as one that has been in place for less time. Movement, tilt, and penetration are early events after implantation that may have an effect on successful filter removal.

Entities:  

Mesh:

Year:  2009        PMID: 19640738     DOI: 10.1016/j.jvir.2009.05.039

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  4 in total

1.  Fractured inferior vena cava filter strut presenting with ST-segment elevation and cardiac tamponade.

Authors:  Dheeraj Khurana; Jaffar Raza; Sunil Abrol; Neil L Coplan
Journal:  Tex Heart Inst J       Date:  2015-04-01

Review 2.  Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type.

Authors:  Steven E Deso; Ibrahim A Idakoji; William T Kuo
Journal:  Semin Intervent Radiol       Date:  2016-06       Impact factor: 1.513

3.  [Who is responsible for the removal of inferior vena cava filters?].

Authors:  D Baschera; J Sebunya; R Zellweger
Journal:  Unfallchirurg       Date:  2012-06       Impact factor: 1.000

4.  A fractured inferior vena cava filter strut migrating to the left pulmonary artery.

Authors:  Tamer Hudali; Ali Zayed; Bernard Karnath
Journal:  Respir Med Case Rep       Date:  2015-06-12
  4 in total