Literature DB >> 19634856

No superiority of cemented metal-on-metal vs metal-on-polyethylene THA at 5-year follow-up.

Wierd P Zijlstra1, John Cheung, Maurits S Sietsma, Jos Jam van Raay, Robert Deutman.   

Abstract

A randomized controlled trial was performed to compare the cemented Stanmore metal-on-metal (Biomet, Warsaw, Indiana) total hip arthroplasty (THA; 102 hips) to the cemented Stanmore metal-on-polyethylene (Biomet) THA (98 hips). The primary outcome was clinical performance. Radiological performance, serum cobalt analysis, and prosthetic survival were secondary outcome measures. At a mean follow-up of 5.6 years, 5 patients were lost to follow-up, 18 died, and 4 were revised (3 metal-on- metal, 1 metal-on-polyethylene). Harris Hip Scores improved from 48 to 90 in the metal-on-metal patients (P<.001) and from 46 to 87 in the metal-on-polyethylene patients (P<.001). Oxford Hip Scores changed from 40 to 19 in the metal-on-metal group (P<.001) and from 40 to 18 in the metal-on-polyethylene group (P<.001). For both Harris and Oxford Hip Scores, there was no significant difference between the 2 groups. Five-year survival with revision for any reason was 97% (95% CI 93%-100%) in the metal-on-metal group and 99% (95% CI 97%-100%) in the metal-on-polyethylene group. All revisions were indicated for aseptic loosening (metal-on-metal: 3 cup revisions; metal-on-polyethylene: 1 total revision). At 5-year follow-up, cemented metal-on-metal THA showed no clinical superiority over metal-on-polyethylene THA.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19634856     DOI: 10.3928/01477447-20090527-06

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  10 in total

Review 1.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Do "premium" joint implants add value?: analysis of high cost joint implants in a community registry.

Authors:  Terence J Gioe; Amit Sharma; Penny Tatman; Susan Mehle
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

3.  Cumulative revision rate is higher in metal-on-metal THA than metal-on-polyethylene THA: analysis of survival in a community registry.

Authors:  Der-Chen T Huang; Penny Tatman; Susan Mehle; Terence J Gioe
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

Review 4.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

5.  High rate of infection after aseptic revision of failed metal-on-metal total hip arthroplasty.

Authors:  Cody C Wyles; Robert E Van Demark; Rafael J Sierra; Robert T Trousdale
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 6.  How have alternative bearings and modularity affected revision rates in total hip arthroplasty?

Authors:  William M Mihalko; Markus A Wimmer; Carol A Pacione; Michel P Laurent; Robert F Murphy; Carson Rider
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

Review 7.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

Review 8.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

9.  Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty.

Authors:  Rinne M Peters; Pax Willemse; Paul C Rijk; Mels Hoogendoorn; Wierd P Zijlstra
Journal:  Case Rep Orthop       Date:  2017-08-27

10.  Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty.

Authors:  Hugo C van der Veen; Inge Hf Reininga; Wierd P Zijlstra; Martijn F Boomsma; Sjoerd K Bulstra; Jos Jam van Raay
Journal:  Hip Int       Date:  2019-03-06       Impact factor: 2.135

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.