Literature DB >> 19634744

Anterior segment optical coherence tomography as a screening tool for the assessment of the anterior segment angle.

Melike Pekmezci1, Travis C Porco, Shan C Lin.   

Abstract

BACKGROUND AND
OBJECTIVE: Anterior segment optical coherence tomography (AS-OCT) is an alternative method for the assessment of angle width. The purpose of this study is to assess the accuracy of AS-OCT for detecting occludable angles and compare the results of high- and low-resolution images with gonioscopy. PATIENTS AND METHODS: Visante AS-OCT (Carl Zeiss Meditec, Dublin, CA) images of 303 eyes (155 patients) presenting between February 1 and July 15, 2007, were retrospectively analyzed. Angle recess area (ARA) and angle opening distances (AOD) at 250, 500, and 750 microm were measured and correlated with the corresponding gonioscopic measurements.
RESULTS: AS-OCT parameters showed a nonlinear relationship with gonioscopy, ARA having the highest correlation. Correlations between high- and low-resolution images were modest. Cut-off values were 0.180 mm2 (70.3% sensitivity, 87.4% specificity) for ARA and 0.264 mm (71.8% sensitivity, 84.8% specificity) for AOD at 500 microm.
CONCLUSION: AS-OCT appears to be a promising screening tool for narrow angles.

Entities:  

Mesh:

Year:  2009        PMID: 19634744     DOI: 10.3928/15428877-20096030-07

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  11 in total

Review 1.  Old and new in exploring the anterior chamber angle.

Authors:  Moisescu Raluca; Filip Mircea; Filip Andrei; Dragne Carmen; Nicolae Miruna; Triantafyllidis Grigorios; Ungureanu Ileana
Journal:  Rom J Ophthalmol       Date:  2015 Oct-Dec

2.  Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

Authors:  D S Grewal; G S Brar; R Jain; S P S Grewal
Journal:  Eye (Lond)       Date:  2011-02-18       Impact factor: 3.775

3.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

4.  Reproducibility and Agreement Between 2 Spectral Domain Optical Coherence Tomography Devices for Anterior Chamber Angle Measurements.

Authors:  Kenneth M Marion; Jyotsna Maram; Xiaojing Pan; Anna Dastiridou; ZhouYuan Zhang; Alex Ho; Brian A Francis; Srinivas R Sadda; Vikas Chopra
Journal:  J Glaucoma       Date:  2015-12       Impact factor: 2.503

Review 5.  Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma.

Authors:  Dewang Angmo; Monisha E Nongpiur; Reetika Sharma; Talvir Sidhu; Ramanjit Sihota; Tanuj Dada
Journal:  Oman J Ophthalmol       Date:  2016 Jan-Apr

6.  Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery.

Authors:  Handan Akil; Ping Huang; Vikas Chopra; Brian Francis
Journal:  J Ophthalmol       Date:  2016-10-03       Impact factor: 1.909

7.  Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.

Authors:  Sunee Chansangpetch; Anwell Nguyen; Marta Mora; Mai Badr; Mingguang He; Travis C Porco; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-03-01       Impact factor: 4.799

8.  Quantitative Evaluation of Gonioscopic and EyeCam Assessments of Angle Dimensions Using Anterior Segment Optical Coherence Tomography.

Authors:  Benjamin Y Xu; Anmol A Pardeshi; Bruce Burkemper; Grace M Richter; Shan C Lin; Roberta McKean-Cowdin; Rohit Varma
Journal:  Transl Vis Sci Technol       Date:  2018-12-27       Impact factor: 3.283

9.  Morphological analysis of age-related iridocorneal angle changes in normal and glaucomatous cases using anterior segment optical coherence tomography.

Authors:  Yuko Maruyama; Kazuhiko Mori; Yoko Ikeda; Morio Ueno; Shigeru Kinoshita
Journal:  Clin Ophthalmol       Date:  2013-12-21

Review 10.  Ageing and ocular surface immunity.

Authors:  Alireza Mashaghi; Jiaxu Hong; Sunil K Chauhan; Reza Dana
Journal:  Br J Ophthalmol       Date:  2016-07-04       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.