Literature DB >> 19633965

Vibrational spectroscopy standoff detection of explosives.

Leonardo C Pacheco-Londoño1, William Ortiz-Rivera, Oliva M Primera-Pedrozo, Samuel P Hernández-Rivera.   

Abstract

Standoff infrared and Raman spectroscopy (SIRS and SRS) detection systems were designed from commercial instrumentation and successfully tested in remote detection of high explosives (HE). The SIRS system was configured by coupling a Fourier-transform infrared interferometer to a gold mirror and detector. The SRS instrument was built by fiber coupling a spectrograph to a reflective telescope. HE samples were detected on stainless steel surfaces as thin films (2-30 microg/cm(2)) for SIRS experiments and as particles (3-85 mg) for SRS measurements. Nitroaromatic HEs: TNT, DNT, RDX, C4, and Semtex-H and TATP cyclic peroxide homemade explosive were used as targets. For the SIRS experiments, samples were placed at increasing distances and an infrared beam was reflected from the stainless steel surfaces coated with the target chemicals at an angle of approximately 180 degrees from surface normal. Stainless steel plates containing TNT and RDX were first characterized for coverage distribution and surface concentration by reflection-absorption infrared spectroscopy. Targets were then placed at the standoff distance and SIRS spectra were collected in active reflectance mode. Limits of detection (LOD) were determined for all distances measured for the target HE. LOD values of 18 and 20 microg/cm(2) were obtained for TNT and RDX, respectively, for the SIR longest standoff distance measured. For SRS experiments, as low as 3 mg of TNT and RDX were detected at 7 m source-target distance employing 488 and 514.5 nm excitation wavelengths. The first detection and quantification study of the important formulation C4 is reported. Detection limits as function of laser powers and acquisition times and at a standoff distance of 7 m were obtained.

Entities:  

Year:  2009        PMID: 19633965     DOI: 10.1007/s00216-009-2954-y

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  A nanosensor for TNT detection based on molecularly imprinted polymers and surface enhanced Raman scattering.

Authors:  Ellen L Holthoff; Dimitra N Stratis-Cullum; Mikella E Hankus
Journal:  Sensors (Basel)       Date:  2011-03-01       Impact factor: 3.576

2.  Surface Persistence of Trace Level Deposits of Highly Energetic Materials.

Authors:  Leonardo C Pacheco-Londoño; José L Ruiz-Caballero; Michael L Ramírez-Cedeño; Ricardo Infante-Castillo; Nataly J Gálan-Freyle; Samuel P Hernández-Rivera
Journal:  Molecules       Date:  2019-09-26       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.