Literature DB >> 19632026

Non-invasive central venous pressure measurement by compression ultrasound--a step into real life.

Christoph Thalhammer1, Martin Siegemund, Markus Aschwanden, Mirjam Gassmann, Ulrich A Baumann, Kurt A Jaeger, Stephan Imfeld.   

Abstract

AIM OF THE STUDY: Information on central venous pressure (CVP) is helpful in clinical situations like cardiac failure and sepsis. Compression ultrasound (CU) of a forearm vein has been shown to be a reliable method for CVP measurement when assessed by experienced personal under study conditions. To test the hypothesis, that CU can be reliably used for CVP measurement after a training program and using a portable ultrasound system, we investigated feasibility and accuracy of CU, comparing the results of vascular experts vs. trainees as well as high-end vs. a portable ultrasound system.
METHODS: CU with non-invasive CVP measurement (CVP(ni)) was performed by four investigators in 50 patients of an intensive care unit and compared with invasive CVP measurement (CVP(i)).
RESULTS: Feasibility was between 88 and 92% in the different investigator groups. CVP(ni) measurement showed a significant linear correlation (r=0.58-0.68; p<0.001) with CVP(i) in all groups. Mean difference between CVP(i) and CVP(ni) was 2.4+/-3.1mmHg and similar between the investigators. No differences were observed between measurements done by vascular experts and trainees, as well as between high-end and portable ultrasound systems. Further we demonstrated, that CU is able to detect changes in CVP during the respiratory cycle.
CONCLUSIONS: After a training program CU can be used by non-vascular clinician for reliable CVP measurement with good quality portable systems. Furthermore, respiratory changes in CVP are detectable by CU. These data suggest CU to be an efficient method for measuring CVP under real life conditions.

Entities:  

Mesh:

Year:  2009        PMID: 19632026     DOI: 10.1016/j.resuscitation.2009.06.027

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  5 in total

1.  A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home.

Authors:  Emanuela Marcelli; Laura Cercenelli; Barbara Bortolani; Saverio Marini; Luca Arfilli; Alessandro Capucci; Gianni Plicchi
Journal:  Med Devices (Auckl)       Date:  2021-05-13

2.  Changing trends of hemodynamic monitoring in ICU - from invasive to non-invasive methods: Are we there yet?

Authors:  Shubhangi Arora; Preet Mohinder Singh; Basavana G Goudra; Ashish C Sinha
Journal:  Int J Crit Illn Inj Sci       Date:  2014-04

3.  Internal jugular pressure increases during parabolic flight.

Authors:  David S Martin; Stuart M C Lee; Timothy P Matz; Christian M Westby; Jessica M Scott; Michael B Stenger; Steven H Platts
Journal:  Physiol Rep       Date:  2016-12

4.  IJV collapsibility index vs IVC collapsibility index by point of care ultrasound for estimation of CVP: a comparative study with direct estimation of CVP.

Authors:  Haitham Mohammed Jassim; Vamanjore A Naushad; Mohamad Yahya Khatib; Prem Chandra; Mohammed Milad Abuhmaira; Sunil Hassan Koya; Mostafa Sayed Ahmed Ellitthy
Journal:  Open Access Emerg Med       Date:  2019-04-03

5.  Ultrasound-Guided Radial Artery Compression to Assess Blood Pressure.

Authors:  Leonard Bunting; Andrew Butki; Ashley Sullivan
Journal:  West J Emerg Med       Date:  2017-02-27
  5 in total