Literature DB >> 19631125

Changes in rotation after implantation of a bag-in-the-lens intraocular lens.

Jos J Rozema1, Laure Gobin, Kristien Verbruggen, Marie-José Tassignon.   

Abstract

PURPOSE: To estimate the rotation stability of the bag-in-the-lens (BIL) intraocular lens (IOL) (Morcher 89A) over time and to assess whether the rotational stability of the IOL design is suitable for toric corrections.
SETTING: Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.
METHODS: This prospective study evaluated patients who had cataract surgery and BIL IOL implantation. Postoperative red reflex photographs were taken 1 day, 5 weeks, and 6 months after surgery. Intraocular lens rotation was obtained by defining a triangle between a scleral blood vessel, the IOL haptic, and the IOL optic center. Changes in the triangle during the follow-up were evaluated using purpose-designed software written in MatLab.
RESULTS: Fifty-nine eyes of 49 patients (mean age 68.0 years +/- 11.9 [SD]) were included. There was little postoperative IOL rotation (mean 0.05 +/- 2.02 degrees) between 1 day and 5 weeks (n = 46 eyes) and between 5 weeks and 6 months (mean 0.36 +/- 1.39 degrees) (n = 15 eyes). The IOL rotation remained unchanged from 1 to 6 months postoperatively (P = .327, analysis of variance). There was no correlation between IOL rotation and patient age (r(2) = 0.011) or IOL power (r(2) = 0.003). Postoperative IOL rotations were not different between left eyes and right eyes (P = .862, t test).
CONCLUSION: The BIL IOL showed good rotation stability, making it suitable for toric correction.

Entities:  

Mesh:

Year:  2009        PMID: 19631125     DOI: 10.1016/j.jcrs.2009.03.037

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  [Corneal ulcer caused by MRSA after UV/riboflavin cross-linking in a patient with bilateral keratoconus].

Authors:  M Bödemann; T Kohnen
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

2.  Influence of rigid lens decentration and rotation on visual image quality in normal and keratoconic eyes.

Authors:  Jos J Rozema; Gareth D Hastings; Marta Jiménez-García; Carina Koppen; Raymond A Applegate
Journal:  Ophthalmic Physiol Opt       Date:  2022-09-16       Impact factor: 3.992

Review 3.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

Review 4.  Toric intraocular lenses: Expanding indications and preoperative and surgical considerations to improve outcomes.

Authors:  Vivek Mahendrapratap Singh; Muralidhar Ramappa; Somasheila I Murthy; Audrey Talley Rostov
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.