Literature DB >> 19629805

Evaluation of a two cursor control device for development of a powered laparoscopic surgical tool.

S R Herring1, M S Hallbeck.   

Abstract

The current study was performed to test two electronic cursor control devices (a Touchpad and a MicroJoystick) for use in an articulating powered laparoscopic tool. A simple target acquisition test was conducted to test how well the cursor control devices could be manipulated and how accurate they were (including endpoint and movement path). The study varied the width (0.27, 0.54 and 1.07 cm) of the target as well as the hand position used (thumb and index finger control). Additionally, each participant was able to choose their ideal operating cursor speed for each cursor control device. The MicroJoystick had a higher throughput and movement variability than the Touchpad. In all other categories tested, the cursor control devices did not differ significantly. The speed of the cursor control devices did not affect the performance of the devices; therefore, the ideal cursor speed could be chosen by the participant. Finally, the hand position did not affect the performance of the devices. This experiment found both hand positions, cursor control devices and all speeds could be used to effectively manipulate an articulating end-effector in a powered, cauterising, laparoscopic tool. This article addresses the advantages and limitations of two control mechanisms for laparoscopic tool controls considering both the subjective and objective data. The controls are tested in two hand positions to test how well the participants can manipulate the device while minimising perceived fatigue.

Entities:  

Mesh:

Year:  2009        PMID: 19629805     DOI: 10.1080/00140130802645198

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  3 in total

Review 1.  Impact of Design on Medical Device Safety.

Authors:  Teodora Miclăuş; Vasiliki Valla; Angeliki Koukoura; Anne Ahlmann Nielsen; Benedicte Dahlerup; Georgios-Ioannis Tsianos; Efstathios Vassiliadis
Journal:  Ther Innov Regul Sci       Date:  2019-12-09       Impact factor: 1.778

2.  The investigation of laparoscopic instrument movement control and learning effect.

Authors:  Chiuhsiang Joe Lin; Hung-Jen Chen
Journal:  Biomed Res Int       Date:  2013-07-24       Impact factor: 3.411

3.  Quality and safety of minimally invasive surgery: past, present, and future.

Authors:  Bernadette McCrory; Chad A LaGrange; Ms Hallbeck
Journal:  Biomed Eng Comput Biol       Date:  2014-04-21
  3 in total