Literature DB >> 19629555

A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.

James Courtney Parker1, Adel Sakla, Francis M Donovan, David Beam, Annu Chekuri, Mohammad Al-Khatib, Charles R Hamm, Fabien G Eyal.   

Abstract

A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19629555     DOI: 10.1007/s11517-009-0517-1

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  36 in total

Review 1.  Treatment of ARDS.

Authors:  R G Brower; L B Ware; Y Berthiaume; M A Matthay
Journal:  Chest       Date:  2001-10       Impact factor: 9.410

2.  Development and application of a double-piston configured, total-liquid ventilatory support device.

Authors:  J P Meinhardt; M Quintel; R B Hirschl
Journal:  Crit Care Med       Date:  2000-05       Impact factor: 7.598

3.  Negative slope of exhaled CO2 profile: implications for ventilation heterogeneity during partial liquid ventilation.

Authors:  E A Mates; P Tarczy-Hornoch; J Hildebrandt; J C Jackson; M P Hlastala
Journal:  Adv Exp Med Biol       Date:  1996       Impact factor: 2.622

4.  Helium versus oxygen for tracheal gas insufflation during mechanical ventilation.

Authors:  R Pizov; A Oppenheim; L A Eidelman; Y G Weiss; C L Sprung; S Cotev
Journal:  Crit Care Med       Date:  1998-02       Impact factor: 7.598

Review 5.  Partial liquid ventilation for preventing death and morbidity in adults with acute lung injury and acute respiratory distress syndrome.

Authors:  M W Davies; J F Fraser
Journal:  Cochrane Database Syst Rev       Date:  2004-10-18

6.  Continuous tracheal gas insufflation during partial liquid ventilation in juvenile rabbits with acute lung injury.

Authors:  Guangfa Zhu; Thomas H Shaffer; Marla R Wolfson
Journal:  J Appl Physiol (1985)       Date:  2003-12-19

7.  A prototype of a liquid ventilator using a novel hollow-fiber oxygenator in a rabbit model.

Authors:  Stefano Tredici; Eisaku Komori; Akio Funakubo; David O Brant; Joseph L Bull; Robert H Bartlett; Ronald B Hirschl
Journal:  Crit Care Med       Date:  2004-10       Impact factor: 7.598

Review 8.  Devices for rapid induction of hypothermia.

Authors:  M Holzer
Journal:  Eur J Anaesthesiol Suppl       Date:  2008

9.  Bronchioalveolar lavage with perfluorochemical liquid during conventional ventilation.

Authors:  Rolf Lindemann; Thomas Rajka; Thore Henrichsen; Ole Georg Vinorum; Charlotte de Lange; Aage Erichsen; Drude Fugelseth
Journal:  Pediatr Crit Care Med       Date:  2007-09       Impact factor: 3.624

10.  Alterations of alveolar type II cells and intraalveolar surfactant after bronchoalveolar lavage and perfluorocarbon ventilation. An electron microscopical and stereological study in the rat lung.

Authors:  Mario Rüdiger; Sebastian Wendt; Lars Köthe; Wolfram Burkhardt; Roland R Wauer; Matthias Ochs
Journal:  Respir Res       Date:  2007-06-05
View more