Literature DB >> 19629544

Effect of exposure time on the color stability of resin-based restorative materials when polymerized with quartz-tungsten halogen and LED light.

Stefan Rüttermann1, Kim Suyoun, Wolfgang H-M Raab, Ralf Janda.   

Abstract

The objective of this study was to investigate the effect of exposure time on color stability of resin-based restorative materials when polymerized with quartz-tungsten halogen light (QTH) or light-emitting diode light (LED). Eight samples of Ceram-X Mono, Dyract eXtra, and Tetric EvoCeram each were cured for 10, 20, and 60 s with QTH or LED. The CIE-Lab values (L*, a*, b*) were measured prior to and after performing water storage or a Suntest, and ΔL, Δa, Δb, and ΔE were calculated. Statistical analysis (p < 0.05) showed significant changes of the color values after each of the aging processes as well as between ΔL, Δa, Δb, and ΔE of the materials in dependence of the curing device, exposure time, aging condition, and material formulation. LED performed similarly or even better with 10-s exposure time than QTH with 20 s. No improvement of color stability was achieved with increasing exposure time of 60 s either for LED or for QTH. Exposure time, emission spectrum of the light-curing device, as well as the individual material formulation influence color stability. There is apparently an exposure time above which the individual material formulation, especially type and amount of photoinitiator or synergist, dominate the color stability.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19629544     DOI: 10.1007/s00784-009-0316-y

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  28 in total

1.  Color stability of resin matrix restorative materials as a function of the method of light activation.

Authors:  Ralf Janda; Jean-François Roulet; Martin Kaminsky; Glenn Steffin; Mark Latta
Journal:  Eur J Oral Sci       Date:  2004-06       Impact factor: 2.612

2.  The effect of curing units and staining solutions on the color stability of resin composites.

Authors:  A Rüya Yazici; Cigdem Celik; Berrin Dayangaç; Gül Ozgünaltay
Journal:  Oper Dent       Date:  2007 Nov-Dec       Impact factor: 2.440

3.  In vitro effect of light-emitting diode light polymerization on the color stability of three resin-based restorative materials.

Authors:  Stefan Rüttermann; Andrea Servos; Wolfgang H-M Raab; Ralf Janda
Journal:  Acta Odontol Scand       Date:  2008-02       Impact factor: 2.331

4.  Effect of energy density on color stability in dental resin composites under accelerated aging.

Authors:  Eliezer Zamarripa; Adriana L Ancona; Norma B D'Accorso; Ricardo L Macchi; Pablo F Abate
Journal:  Acta Odontol Latinoam       Date:  2008

5.  Conventional and microfilled composite resins. Part I: Color stability and marginal adaptation.

Authors:  C Ameye; P Lambrechts; G Vanherle
Journal:  J Prosthet Dent       Date:  1981-12       Impact factor: 3.426

6.  Leaking of fillers in dental composites.

Authors:  K J Söderholm
Journal:  J Dent Res       Date:  1983-02       Impact factor: 6.116

7.  Halogen and LED light curing of composite: temperature increase and Knoop hardness.

Authors:  L F Schneider; S Consani; L Correr-Sobrinho; A B Correr; M A Sinhoreti
Journal:  Clin Oral Investig       Date:  2006-01-10       Impact factor: 3.573

8.  Color stability of acrylic resin adhesives with different initiation modes.

Authors:  Naomi Tanoue; Yoshikazu Koishi; Hiroaki Yanagida; Mitsuru Atsuta; Kazuki Shimada; Hideo Matsumura
Journal:  Dent Mater J       Date:  2004-09       Impact factor: 2.102

9.  Investigation of polymerisation shrinkage strain, associated cuspal movement and microleakage of MOD cavities restored incrementally with resin-based composite using an LED light curing unit.

Authors:  G J P Fleming; S Khan; O Afzal; W M Palin; F J T Burke
Journal:  J Dent       Date:  2006-07-13       Impact factor: 4.379

10.  Hardness and wear resistance of two resin composites cured with equivalent radiant exposure from a low irradiance LED and QTH light-curing units.

Authors:  Lance C Ramp; James C Broome; Merrie H Ramp
Journal:  Am J Dent       Date:  2006-02       Impact factor: 1.522

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.