Are tensile and compressive Young's moduli of compact bone different?

Meir M Barak1, John D Currey, Steve Weiner, Ron Shahar.   

Abstract

This study examines the question of whether the stiffness (Young's modulus) of secondary osteonal cortical bone is different in compression and tension. Electronic speckle pattern interferometry (ESPI) is used to measure concurrently the compressive and tensile strains in cortical bone beams tested in bending. ESPI is a non-contact method of measuring surface deformations over the entire region of interest of a specimen, tested wet. The measured strain distributions across the beam, and the determination of the location of the neutral axis, demonstrate in a statistically-robust way that the tensile Young's modulus is slightly (6%), but significantly greater than that of the compressive Young's modulus. It is also shown that within a relatively small bone specimen there are considerable variations in the modulus, presumably caused by structural inhomogeneities.

Mesh:

Substances:

Year:  2008        PMID: 19627807     DOI: 10.1016/j.jmbbm.2008.03.004

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  Secondary osteon structural heterogeneity between the cranial and caudal cortices of the proximal humerus in white-tailed deer.

Authors:  Jack T Nguyen; Meir M Barak
Journal:  J Exp Biol       Date:  2020-06-11       Impact factor: 3.312

2.  One-Dimensional Theoretical Solution and Two-Dimensional Numerical Simulation for Functionally-Graded Piezoelectric Cantilever Beams with Different Properties in Tension and Compression.

Authors:  He Xiao-Ting; Yang Zhi-Xin; Jing Hong-Xia; Sun Jun-Yi
Journal:  Polymers (Basel)       Date:  2019-10-23       Impact factor: 4.329

Review 3.  Biomechanics and mechanobiology of the bone matrix.

Authors:  Chunyang Ma; Tianming Du; Xufeng Niu; Yubo Fan
Journal:  Bone Res       Date:  2022-08-30       Impact factor: 13.362

4.  Is the 0.2%-Strain-Offset Approach Appropriate for Calculating the Yield Stress of Cortical Bone?

Authors:  Guanjun Zhang; Junjie Luo; Gang Zheng; Zhonghao Bai; Libo Cao; Haojie Mao
Journal:  Ann Biomed Eng       Date:  2021-01-21       Impact factor: 3.934

5.  Modeling of Bimodular Bone Specimen under Four-Point Bending Fatigue Loading.

Authors:  Yufan Yan; Xianjia Meng; Chuanyong Qu
Journal:  Materials (Basel)       Date:  2022-01-08       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.