Literature DB >> 1962721

Reliability of an isokinetic dorsiflexion and plantar flexion apparatus.

D Wennerberg1.   

Abstract

The insufficient amount of research to support high reliability of isokinetic ankle joint adaptations indicates a need for study in this area. Certain brands of isokinetic machinery and specific joint apparatuses have been studied for consistency in adequate numbers of investigations, while there has been little research done on other brands and all other joint adaptations besides the knee. We studied the Biodex B-2000 dorsiflexion and plantar flexion adaptation for reliability between two trials of contractions measuring peak torque. Our results showed generally low reliability coefficients between trials in every condition tested with respect to each ankle motion and two different isokinetic speeds. No connection was seen between ankle motion and isokinetic speed with respect to reliability. Attempts to pinpoint reasons behind inconsistencies concentrate upon such areas as the subject testing position, time between trials, and machine structure. Areas of further study might deal with different brands of isokinetic devices and also the different joint adaptations.

Entities:  

Mesh:

Year:  1991        PMID: 1962721     DOI: 10.1177/036354659101900519

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  7 in total

1.  Factors Contributing to Chronic Ankle Instability: A Strength Perspective.

Authors:  Thomas W Kaminski; Heather D Hartsell
Journal:  J Athl Train       Date:  2002-12       Impact factor: 2.860

Review 2.  Strength and power assessment. Issues, controversies and challenges.

Authors:  P Abernethy; G Wilson; P Logan
Journal:  Sports Med       Date:  1995-06       Impact factor: 11.136

3.  The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance.

Authors:  Michael Möller; Karin Lind; Jorma Styf; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-11-22       Impact factor: 4.342

4.  Clinical assessment is sufficient to allow outcome evaluation following surgical management of Achilles tendon ruptures.

Authors:  Atanas Todorov; Frederic Schaub; Fabian Blanke; Patricia Heisterbach; Franciska Sachser; Andreas Gösele; Martin Majewski
Journal:  Muscles Ligaments Tendons J       Date:  2015-07-03

5.  Which Treatment is More Effective for Functional Ankle Instability: Strengthening or Combined Muscle Strengthening and Proprioceptive Exercises?

Authors:  Ki-Jong Kim; Young-Eok Kim; Hyun-Ju Jun; Jin-Su Lee; Sung-Ha Ji; Sang-Goo Ji; Tae-Hwa Seo; Young-Ok Kim
Journal:  J Phys Ther Sci       Date:  2014-03-25

6.  Association of arch height with ankle muscle strength and physical performance in adult men.

Authors:  X Zhao; T Tsujimoto; B Kim; K Tanaka
Journal:  Biol Sport       Date:  2017-01-01       Impact factor: 2.806

7.  Reliability of Ankle⁻Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer.

Authors:  Zuzana Gonosova; Petr Linduska; Lucia Bizovska; Zdenek Svoboda
Journal:  Medicina (Kaunas)       Date:  2018-06-04       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.