Literature DB >> 19626530

Man-made vitreous fibers in office buildings in the Helsinki area.

Heidi J Salonen1, Sanna K Lappalainen, Henri M Riuttala, Antti P Tossavainen, Pertti O Pasanen, Kari E Reijula.   

Abstract

Several sources of man-made vitreous fibers (MMVFs) may exist in an office environment causing irritation symptoms among occupants. In 258 office buildings, the occurrence and density of settled MMVFs on surfaces were measured by two sampling methods. Altogether, 1113 samples of settled dust were collected from surfaces with plastic bags and gelatine tape and were analyzed with a scanning electron microscope and a stereomicroscope, respectively. Tape samples from 68 buildings were collected from frequently cleaned (n = 162) and seldom cleaned (n = 57) room surfaces in 56 and 29 offices, respectively, and from supply air ducts (n = 24) in 10 offices. MMVFs longer than 20 microm were counted with a stereomicroscope. Irritation symptoms were recorded with a questionnaire. More than 60% of the surface dust and almost 90% of the samples collected from supply air ducts contained MMVFs. The density of MMVFs longer than 20 microm ranged from < 0.1 to 5 fiber cm(- 2). The mean density of the MMVFs was about two times higher on the seldom cleaned surfaces than on the frequently cleaned surfaces. The density was usually under 0.2 MMVF cm(- 2) in surface dust of offices without emission sources of MMVFs. The measurements combined with qualitative analysis of settled dust can help to localize relevant sources of fiber emissions. Altogether, in 40% of the buildings, several occupants had repeated irritation symptoms that were verified by occupational health care personnel.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19626530     DOI: 10.1080/15459620903133667

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Case studies: evaluation of cut-resistant sleeves and possible fiberglass fiber shedding at a steel mill.

Authors:  Diana M Ceballos; Loren C Tapp; Douglas M Wiegand
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  Observational cross-sectional study on Symptoms Associated to Moisture DAmage at Workplace: the SAMDAW study protocol.

Authors:  Pia Nynäs; Sarkku Vilpas; Elina Kankare; Jussi Karjalainen; Lauri Lehtimäki; Jura Numminen; Antti Tikkakoski; Leenamaija Kleemola; Jukka Uitti
Journal:  BMJ Open       Date:  2019-06-25       Impact factor: 2.692

3.  Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality.

Authors:  Katja Tähtinen; Sanna Lappalainen; Kirsi Karvala; Jouko Remes; Heidi Salonen
Journal:  Int J Environ Res Public Health       Date:  2018-04-04       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.