Literature DB >> 19618451

Reproducibility of same session repeated cystometry and pressure-flow studies in women with symptoms of urinary incontinence.

Suzan R Broekhuis1, Kirsten B Kluivers, Jan C M Hendriks, Elske T Massolt, Jan Groen, Mark E Vierhout.   

Abstract

AIM: The aim of this study was to determine the reproducibility of same session repeated urodynamic measurements in women with symptoms of urinary incontinence.
METHODS: Women presenting with symptoms of urinary incontinence underwent standardized urodynamic examination, which consisted of free uroflowmetry and two filling cystometries and pressure-flow studies. Intra-class Correlation Coefficient (ICC) and McNemar tests were used to describe the same session reproducibility.
RESULTS: Two evaluable urodynamic tests were available in 152 patients. Overall, reproducibility of the urodynamic parameters were good to excellent (ICC range: 0.72-0.93), except for the bladder volume at first sensation of bladder filling (ICC = 0.46) and the maximum Watt's factor (ICC = 0.68). The bladder volume at first sensation and the maximum cystometric capacity were systematically higher in the second run (mean difference (95% CI) = -45 (-73; -37) and -3 (-15; 10), respectively). Reproducibility of the diagnosis stress urinary incontinence and/or detrusor overactivity were good to excellent (median ICC = 0.76, P = 0.68 and P = 1.00, respectively). Reproducibility of the volume and amplitude at involuntary detrusor contractions, however, were only poor (ICC = 0.18 and 0.25, respectively).
CONCLUSIONS: The reproducibility of same session repeated urodynamic measurements in women with symptoms of urinary incontinence was good to excellent. Our results provide the scientific support for guidelines that recommend the omission of repeated filling cystometries and pressure-flow studies in cases where the first test confirms the pathology expected. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 19618451     DOI: 10.1002/nau.20783

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  2 in total

1.  Diagnostic accuracy of single channel cystometry for neurogenic bladder diagnosis following spinal cord injury: a pilot study.

Authors:  Akmal Hafizah Zamli; Kavitha Ratnalingam; Yusma Asni Yusmido; Kuo Ghee Ong
Journal:  Spinal Cord Ser Cases       Date:  2017-05-04

2.  A noninvasive bladder sensory test supports a role for dysmenorrhea increasing bladder noxious mechanosensitivity.

Authors:  Frank F Tu; Aliza E Epstein; Kristen E Pozolo; Debra L Sexton; Alexandra I Melnyk; Kevin M Hellman
Journal:  Clin J Pain       Date:  2013-10       Impact factor: 3.442

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.