Literature DB >> 19618104

Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six cases.

Andrew Lozen1, Sunil Manjila, Richard Rhiew, Richard Fessler.   

Abstract

BACKGROUND: The advent of stent-assisted coil embolization has revolutionized the endovascular management of complex intracranial aneurysms. Although performed routinely in most cerebrovascular centers, there are not many case series reported about the Y-stent technique for coil placement in cerebral aneurysms. The authors present the second largest series available within the neurosurgical literature.
METHODS: The authors have retrospectively reviewed the medical records and angiographic data of six patients who were diagnosed as having unruptured cerebral aneurysms and subsequently treated using "Y" stent-assisted coil embolization. Five out of six cerebral aneurysms in this study were located at the basilar tip while the remaining one was at the left MCA trifurcation. Aneurysms ranged in size from 8-22 mm. All patients were female with ages ranging from 37-70 years. One patient presented with recurrence of an aneurysm previously managed with a balloon-assisted coil embolization. Another patient presented after a failed trial of a balloon-assisted procedure. One patient had originally been diagnosed with multiple aneurysms of varying size and location.
RESULTS: A "Y" configuration was successfully established in all six patients. Five patients have had a symptom-free recovery period at average follow-up period of 36.7 months. The remaining patient is notable for recurrence that was discovered on angiogram 32 months postoperatively.
CONCLUSIONS: The proposed Y-stent technique is a safe and effective option that can be employed in the endovascular reconstruction of unruptured intracranial aneurysms of complex location and orientation. These methods serve as an acceptable alternative in the management of aneurysms traditionally managed with microsurgery. Hemodynamic assessment has shown Y-stenting to be an advantageous therapy option, yet further studies are required to assess these parameters in alternative therapies.

Entities:  

Mesh:

Year:  2009        PMID: 19618104     DOI: 10.1007/s00701-009-0436-9

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  20 in total

1.  Hybrid, Y-configured, dual stent-assisted coil embolization in the treatment of wide-necked bifurcation aneurysms.

Authors:  Erol Akgul; Tugsan Balli; Erol H Aksungur
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

2.  Y-stent-assisted coil embolization of wide-neck intracranial aneurysms. A single center experience.

Authors:  E Akgul; E Aksungur; T Balli; B Onan; D M Yilmaz; S Bicakci; T Erman
Journal:  Interv Neuroradiol       Date:  2011-04-18       Impact factor: 1.610

3.  The impact of stent design on the structural mechanics of the crossing Y-stent: an in vitro study.

Authors:  Chang-Young Lee; Seong-Ho Park; Chang-Hyun Kim; Goetz Benndorf
Journal:  Neuroradiology       Date:  2014-05-28       Impact factor: 2.804

4.  Stent application for the treatment of cerebral aneurysms.

Authors:  Byung Moon Kim; Dong Joon Kim; Dong Ik Kim
Journal:  Neurointervention       Date:  2011-08-31

5.  Y-stent-assisted coil embolization of anterior circulation aneurysms using two Solitaire AB devices: a single center experience.

Authors:  M Martínez-Galdámez; P Saura; J Saura; A Martínez; J M De Campos; A Pérez
Journal:  Interv Neuroradiol       Date:  2012-06-04       Impact factor: 1.610

6.  Endovascular treatment of wide-neck intracranial bifurcation aneurysms with 'Y'-configuration, double Neuroform® stents-assisted coiling technique: Experience in a single center.

Authors:  C Castaño; M Terceño; S Remollo; M R García-Sort; C Domínguez
Journal:  Interv Neuroradiol       Date:  2017-06-06       Impact factor: 1.610

7.  Very late stent thrombosis following the placement of a crossing Y-stent with dual closed-cell stents for the coiling of a wide-necked aneurysm.

Authors:  Chang-Young Lee; Chang-Hyun Kim
Journal:  BMJ Case Rep       Date:  2014-02-27

8.  Retrograde stenting through the posterior cerebral artery in coil embolization of the posterior communicating artery aneurysm.

Authors:  Young Dae Cho; Kang Min Kim; Woong Jae Lee; Hyun-Seung Kang; Jeong Eun Kim; Moon Hee Han
Journal:  Neuroradiology       Date:  2013-03-12       Impact factor: 2.804

9.  "Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms.

Authors:  B Bartolini; R Blanc; S Pistocchi; H Redjem; M Piotin
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

10.  Treatment of a wide-necked aneurysm of the anterior cerebral artery using two Enterprise stents in "Y"-configuration stenting technique and coil embolization: a technical note.

Authors:  Stefan Rohde; Martin Bendszus; Marius Hartmann; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-10-21       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.